Can spatial resolution reveal individual differences in the L:M cone ratio?
نویسندگان
چکیده
We measured spatial resolution in the parafovea for targets designed to isolate either the long-wavelength (L) or the middle-wavelength (M) cones. Landolt C optotypes were presented for 100 ms on a calibrated monitor at an eccentricity of 5° to the left or right of fixation. There were large individual differences in the ratio of the resolution obtained with L targets to that obtained with M targets, and we suggest that these differences reflect variations in the relative sampling densities of L and M cones in the parafovea. In Experiment 1, we measured contrast thresholds for targets of varying size. Among 10 unselected observers, there was a threefold variation in the ratio of the contrast thresholds for the smallest targets. In Experiments 2 and 3, we held contrast constant and we varied size, in order to establish the minimal target that could be discriminated for each of the two classes of cone. In Experiment 2, two groups of observers, selected on the basis of their settings on a flicker-photometric test, showed a highly significant difference in the ratio of the M and L acuities on the spatial task. In Experiment 3, female carriers of protan or deutan deficiencies, classified only on the basis of their sons' phenotypes, also showed a large difference in the ratio of their acuities for M and L targets. In all three experiments, there was a strong correlation between the ratio of M and L spatial acuities and a flicker-photometric measure of relative sensitivity to long- and middle-wavelength light.
منابع مشابه
Individual differences in chromatic (red/green) contrast sensitivity are constrained by the relative number of L- versus M-cones in the eye
Many previous studies have shown that the relative number of long-wavelength-selective (L) versus medium-wavelength-selective (M) cones in the eye influences spectral sensitivity revealed perceptually. Here, we hypothesize that the L:M cone ratio should also influence red/green chromatic contrast sensitivity. To test this, in each subject we derived an estimate of L:M ratio based on her red/gre...
متن کاملFlicker-photometric electroretinogram estimates of L:M cone photoreceptor ratio in men with photopigment spectra derived from genetics.
Relative proportions of long-wavelength-sensitive (L) to middle-wavelength-sensitive (M) cones were estimated by use of the flicker-photometric electroretinogram (ERG). It has been demonstrated that a major source of error in estimates of cone proportions from spectral luminosity functions is the known variation in the lambda(max) of the photopigments [Vision Res. 38, 1961 (1998)]. To correct f...
متن کاملEstimates of L:M cone ratio from ERG flicker photometry and genetics.
Estimates of L:M cone ratio for males with normal color vision were derived using the flicker-photometric electroretinogram (ERG). These were obtained by best fitting ERG spectral sensitivity functions to a weighted sum of long (L)- and middle (M)-wavelength-sensitive cone spectral absorption curves. Using the ERG, measurements can be made with extremely high precision, which leaves variation i...
متن کاملComparison of red-green equiluminance points in humans and macaques: evidence for different L:M cone ratios between species.
The human spectral luminosity function (V(lambda)) can be modeled as the linear sum of signals from long-wavelength-selective (L) and middle-wavelength-selective (M) cones, with L cones being weighted by a factor of approximately 2. This factor of approximately 2 is thought to reflect an approximate 2:1 ratio of L:M cones in the human retina, which has been supported by studies that allow for m...
متن کاملOrganization of the human trichromatic cone mosaic.
Using high-resolution adaptive-optics imaging combined with retinal densitometry, we characterized the arrangement of short- (S), middle- (M), and long- (L) wavelength-sensitive cones in eight human foveal mosaics. As suggested by previous studies, we found males with normal color vision that varied in the ratio of L to M cones (from 1.1:1 to 16.5:1). We also found a protan carrier with an even...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 78 شماره
صفحات -
تاریخ انتشار 2013