Influence of the timing of administration of crystalloid on maternal hypotension during spinal anesthesia for cesarean delivery: preload versus coload

نویسندگان

  • Ah-Young Oh
  • Jung-Won Hwang
  • In-Ae Song
  • Mi-Hyun Kim
  • Jung-Hee Ryu
  • Hee-Pyoung Park
  • Yeong-Tae Jeon
  • Sang-Hwan Do
چکیده

BACKGROUND Prophylactic fluid preloading before spinal anesthesia has been a routine procedure to prevent maternal hypotension during cesarean delivery. Unlike colloid, timing of infusion of crystalloid may be important because of its short stay in intravascular space. We hypothesized that crystalloid loading just after intrathecal injection compared to preload would be more effective in preventing maternal hypotension. METHODS In this prospective controlled study, sixty parturients were randomized to receive 15 ml/kg of crystalloid before (preload group) or after (coload group) intrathecal drug injection for spinal anesthesia. Hypotension was defined if systolic arterial pressure decreased below 80% of baseline and ephedrine was administered to treat hypotension. The incidence of hypotension and the total dose of ephedrine were checked. Blood pressure, heart rate and nausea before childbirth were assessed. Neonatal outcomes were evaluated with Apgar scores and umbilical blood gas analysis. RESULTS The incidence of hypotension was lower in the coload group compared to the preload group (53% vs. 83%, P = 0.026). The blood pressure showed the bigger drop during spinal anesthesia in the preload group (34 ± 13 vs. 25 ± 10 mmHg, P = 0.002) and smaller dose of ephedrine was required in the coload group (7.5 [0-30] vs. 15 [0-40] mg, P = 0.015). The incidence of nausea was also lower in the coload group (27% vs. 60%, P = 0.019). Neonatal outcome measures were comparable between two groups. CONCLUSIONS In case of using crystalloids for cesarean delivery, coload is more effective than preload for the prevention of maternal hypotension after spinal anesthesia. TRIAL REGISTRATION Clinical Research Information Service KCT0000324 (Jan 12(th), 2012).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crystalloid Coload Reduced the Incidence of Hypotension in Spinal Anesthesia for Cesarean Delivery, When Compared to Crystalloid Preload: A Meta-Analysis

Objective To determine whether crystalloid infusion just after intrathecal injection (coload) would be better than infusion before anesthesia (preload) for hypotension prophylaxis in spinal anesthesia for cesarean delivery. Methods We searched PubMed, EMBASE, Cochrane Central Register of Controlled Trials, and other databases for randomized controlled trials comparing coload of crystalloid wi...

متن کامل

Effect of timing of fluid bolus on reduction of spinal-induced hypotension in patients undergoing elective cesarean delivery.

Spinal-induced hypotension remains the most common complication associated with spinal anesthesia for cesarean delivery. Recent evidence indicates that a 20-mL/kg bolus via pressurized infusion system administered at the time of subarachnoid block (SAB) (coload) may provide better prophylaxis than the traditional administration of a 20-mL/kg crystalloid infusion (preload) approximately 20 minut...

متن کامل

Preload or coload for spinal anesthesia for elective Cesarean delivery: a meta-analysis.

BACKGROUND Hypotension following spinal anesthesia for Cesarean delivery is common. Fluid loading is recommended to prevent hypotension, but preload is often ineffective. In non-pregnant patients, coloading has been shown to better maintain cardiac output after spinal anesthesia. The purpose of this meta-analysis was to determine whether the timing of the fluid infusion, before (preload) or dur...

متن کامل

Ventilatory management of severe acute respiratory failure for Y2K.

condition of mother and infant at cesarean section. Anesth Analg 1969; 48:986–93 8. Clark RB, Thompson DS, Thompson CH: Prevention of spinal hypotension associated with cesarean section. ANESTHESIOLOGY 1976; 45:670–4 9. Russell IF: Effect of posture during the induction of subarachnoid analgesia for caesarean section. Right v left lateral. Br J Anaesth 1987; 59:342–6 10. Norris MC: Hypotension ...

متن کامل

The effects of an increase of central blood volume before spinal anesthesia for cesarean delivery: a qualitative systematic review.

UNLABELLED We evaluated in this qualitative systematic review the efficacy of increasing central blood volume on the incidence of hypotension after spinal anesthesia for elective cesarean delivery. Randomized controlled trials investigating any method of increasing central blood volume before the initiation of obstetric spinal anesthesia were sought by using MEDLINE (1966-2000), Embase (January...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014