Time-gating improves the spatial resolution of STED microscopy.
نویسندگان
چکیده
Stimulated-emission depletion (STED) microscopy improves image resolution by encoding additional spatial information in a second stimulated-decay channel with a spatially-varying strength. Here we demonstrate that spatial information is also encoded in the fluorophore lifetime and that this information can be used to improve the spatial resolution of STED microscopy. By solving a kinetic model for emission in the presence of a time-varying STED pulse, we derive the effective resolution as a function of fluorophore lifetime and pulse duration. We find that the best resolution for a given pulse power is achieved with a pulse of infinitesimally short duration; however, the maximum resolution can be restored for pulses of finite duration by time-gating the fluorescence signal. In parallel, we consider time-gating in the presence of a continuous-wave (CW) STED beam and find that time-gating produces theoretically unbounded resolution with finite laser power. In both cases, the cost of this improved resolution is a reduction in the brightness of the final image. We conclude by discussing situations in which time-gated STED microscopy (T-STED) may provide improved microscope performance beyond an increase in resolution.
منابع مشابه
STED Nanoscopy with Time-Gated Detection: Theoretical and Experimental Aspects
In a stimulated emission depletion (STED) microscope the region in which fluorescence markers can emit spontaneously shrinks with continued STED beam action after a singular excitation event. This fact has been recently used to substantially improve the effective spatial resolution in STED nanoscopy using time-gated detection, pulsed excitation and continuous wave (CW) STED beams. We present a ...
متن کاملSupercontinuum stimulated emission depletion fluorescence lifetime imaging.
Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The ...
متن کاملUpgrade of a Scanning Confocal Microscope to a Single-Beam Path STED Microscope
By overcoming the diffraction limit in light microscopy, super-resolution techniques, such as stimulated emission depletion (STED) microscopy, are experiencing an increasing impact on life sciences. High costs and technically demanding setups, however, may still hinder a wider distribution of this innovation in biomedical research laboratories. As far-field microscopy is the most widely employe...
متن کاملNanoparticle-Assisted STED Nanoscopy with Gold Nanospheres
We demonstrate stimulated emission depletion (STED) microscopy with 20 nm gold nanospheres coated by fluorescently doped silica. We demonstrate significantly improved spatial resolution down to 75 nm, which is the first time that hybrid NPs are used in STED imaging beyond the diffraction limit of confocal microscopy. Unlike previous demonstrations of super-resolution with metal nanoparticles wi...
متن کاملFar-field optical nanoscopy based on continuous wave laser stimulated emission depletion.
Stimulated emission depletion (STED) microscopy is one of the breakthrough technologies that belong to far-field optical microscopy and can achieve nanoscale spatial resolution. We demonstrate a far-field optical nanoscopy based on continuous wave lasers with different wavelengths, i.e., violet and green lasers for excitation and STED, respectively. Fluorescent dyes Coumarin 102 and Atto 390 ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 19 5 شماره
صفحات -
تاریخ انتشار 2011