Abnormal Indicator Dilution Patterns in Dogs Produced by Flowmeter Probes on the Pulmonary Artery.

نویسندگان

  • I J FOX
  • A R CASTANEDA
  • K C WEBER
چکیده

• Indicator dilution technics have been employed by Malooly and co-workers J for the in vivo calibration of electromagnetic flowmeter probes. In attempting to apply this calibration procedure to the measurement of pulmonary arterial flow in anesthetized dogs, we noted that the presence of the flowmeter probe on the pulmonary artery was frequently associated with abnormal indicator dilution curves. In 16 out of 32 experiments the indicator dilution curves were so abnormal that they could not be used to calculate flow as required for calibration of the flowmeter probes. The abnormal curves resembled those observed in the presence of left-to-right shunts; typical examples are shown in figure 1. The possibility that slight constriction or immobilization of the pulmonary artery could interfere so drastically with normal distribution of dye seemed to warrant further investigation. The following experiments show clearly that mechanical interference with the pulmonary artery, incident to placement of electromagnetic flow probes around the artery, can indeed produce striking abnormalities in indicator dilution curves recorded at the femoral artery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical note: measuring portal blood flow in sheep using an ultrasonic transit time flow probe.

Our objective was to validate the use of an ultrasonic transit-time flowmeter for the measurement of portal blood flow (PBF) in sheep. Data recorded with this technique were compared with those obtained with an indicator dilution method, and probes were calibrated in vivo. Wethers were fitted with catheters in the portal, jejunal, and ruminal veins and in a mesenteric artery. Ultrasonic flow pr...

متن کامل

A transfer function analysis of coronary and renal circulation calculated from upstream and downstream indicator-dilution curves.

A method has been developed for computing the distribution of blood transit times (transfer function) from indicator-dilution curves recorded from upstream (aorta) and downstream (pulmonary artery, renal vein and coronary sinus) circulatory sites in mongrel dogs. The method employs a Fourier series transformation of the upstream and downstream curves and yields a time-domain transfer function w...

متن کامل

Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.

A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of bot...

متن کامل

An appraisal of the double indicator-dilution method for the estimation of mitral regurgitation in human subjects.

T HE shape of an indicator-dilution curve is determined by at least 4 variables: cardiac output, the volume between the injection site and the sampling site, the presence of a left-to-right intracardiac shunt, and the presence of valvular regurgitation.1-3 In the absence of an intracardiac shunt and valvular regurgitation, one can predict the downslope of the arterial dilution curve, using the ...

متن کامل

Role of platelet-activating factor in pulmonary edema after coronary ligation in dogs.

To evaluate whether PAF is related to the precipitation of pulmonary edema after myocardial ischemia, we studied the effect of a specific PAF antagonist, CV-6209, on the extravascular lung water level measured by the thermal-dye double indicator dilution method, ETV, after coronary ligation in dogs. Eight dogs served as sham control animals (group 1). The proximal left anterior descending coron...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 15  شماره 

صفحات  -

تاریخ انتشار 1964