A health indicator method for degradation detection of electronic products

نویسندگان

  • Sachin Kumar
  • Nikhil M. Vichare
  • Eli Dolev
  • Michael G. Pecht
چکیده

A methodology for detecting the gradual health degradation of electronic products is presented by defining a health indicator to represent a product’s health state in a time interval. A health indicator is defined as the weighted sum of a histogram bin’s fractional contribution in a time interval that is based on the data collection rate, the likelihood of change in a product’s performance, and a user’s readiness to accept risk. The unified distance measure, Mahalanobis distance (MD), is used to create histograms where optimal bin-width is calculated using a kernel estimator. Summarization of a product’s performance in a time interval for health and degradation estimation together with the behavior of the MD values can reduce false alarms regarding the presence of fault and increase the capability of detecting intermittent and ‘‘no fault found’’ events. A case study performed on computers is presented. A healthy baseline for the computers was created and a threshold for both fault detection and degradation identification was defined. After fault injection into one of the computers, the increase in the MD values detected the initial change in performance parameters. After a short time period, the health indicator detected the degradation whereas the MD values returned to below threshold as the degradation in this case study was an aftereffect of the damaging

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis

During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...

متن کامل

Cytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis

During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...

متن کامل

Fabricant and characterization of SrWO4 and novel silver-doped SrWO4 using co-precipitation method: their photocatalytic performances for methyl orange degradation

A simple co-presipitation method has been developed to synthesize SrWO4 and Ag°-SrWO4 micro/nanostructures with different morphologies, including platelet-, star- and flower-like, in the presence of Na(B(C6H5)) as surfactant. The formation of platelet-, star- and flower-like shapes of particulate system was examined by electron microscopy technique. The products were characterized by X-ray diff...

متن کامل

Stability-indicating UFLC method for uncoupling and estimation of impurities in clopidogrel, aspirin and omeprazole in their tablet dosage form using PDA detection

In this paper a fast and novel stability-indicating ultra fast LC method for separation and estimation of impurities in clopidogrel and aspirin in their combined tablet dosage form and omeprazole was developed. The separation of USP related substances of clopidogrel (A, B and C), aspirin (D), omeprazole (A, B and C) and few other unknown impurities was detected by using ultra fast liquid chroma...

متن کامل

Investigation of Behavior of Forced Degradation of Lidocaine HCl by NMR Spectroscopy and GC-FID Methods: Validation of GC-FID Method for Determination of Related Substance in Pharmaceutical Formulations

  The forced degradation study of lidocaine HCl was carried out according to the ICH guideline Q1A (R2). The degradation conditions were assessed to be hydrolysis, oxidation, photolysis and dry heat during 24 h, 48 h and 72 h and then the samples were investigated by GC-FID method and nuclear magnetic resonance (NMR) spectroscopy. According to these results, the degradation products were not o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Microelectronics Reliability

دوره 52  شماره 

صفحات  -

تاریخ انتشار 2012