A new counting chamber for the eosinophil count.

نویسنده

  • T MANNERS
چکیده

During the past four years numerous articles have been published in which eosinophil counts have been used in the control of therapy by A.C.T.H. In most of these the counts have been performed by using four Fuchs-Rosenthal counting chambers for each count. The author also used these counting chambers for the experimental work on a new diluent for eosinophil counts (Manners, 1951), but found the method cumbersome. Much time was wasted in filling and cleaning four counting chambers when only one should have been necessary. While counting, it was necessary to move to the next counting chamber three times and to refocus if the counting chambers were of different thickness. These disadvantages are obviated by the use of a new counting chamber* designed by the author. The ruling in the new chamber is similar to that of the Fuchs-Rosenthal in that it is composed of large squares 1 mm. x 1 mm., each divided into 16 smaller squares. The ruled area is 4 mm. x 12.5 mm., and the depth of the chamber is 0.2 mm. The whole ruled area is counted and the volume enclosed by it is 10 c.mm. As the dilution of blood is 1 : 10, no calculation is required to find the number of eosinophils per c.mm. When using four Fuchs-Rosenthal chambers the number counted has to be divided by 1.28 to obtain the number of eosinophils per c.mm. Plum (1936) showed that the accuracy attainable in chamber counting depends for the most part on the number of cells per sample counted. There is a great variation due to chance distribution in the number of cells from sample to sample of a given blood, and its standard deviation (S.D.) is equal to the square root of the mean number of cells per sample. As the volume of fluid contained in the new counting chamber is slightly smaller than the total volume contained in four FuchsRosenthal counting chambers, the accuracy of the count is slightly less. The theoretical accuracies of the two counting techniques can be compared by taking an example. With a blood containing 100 eosinophils per c.mm., the counts obtained in the new counting chamber would average 100 cells. The S.D. of their variation due to chance would be 4 100=10, which is 10% of the mean. Using four Fuchs-Rosenthal chambers, which have a total volume of 12.8 c.mm., the count would average 128 cells. The S.D. in this case would be V 128= 11.3, which is 8.8% of the mean. With 100 eosinophils per c.mm. the comparison is thus between an S.D. of 10% and 8.8%. The difference will be less at higher levels and greater at lower levels. The difference is small and the accuracy attainable in the new chamber is sufficient for routine counting of eosinophils.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Evaluation of The Depth of Six Kinds of Sperm Counting Chambers for both Manual and Computer-Aided Semen Analyses

Background Although the depth of the counting chamber is an important factor influencing sperm counting, no research has yet been reported on the measurement and comparison of the depth of the chamber. We measured the exact depths of six kinds of sperm counting chambers and evaluated their accuracy. MaterialsAndMethods In this prospective study, the depths of six kinds of sperm counting chamber...

متن کامل

Basophil counting with a new staining method using alcian blue.

Difficulties in obtaining reproducible and accurate enumeration of circulating basophils with existing techniques have hampered investigation of this infrequent cell population. A new basophil staining method is described that employs alcian blue dye for staining of heparin within basophils at low pH and in the presence of lanthanum ions. Basophil recognition is facilitated by reducing nonspeci...

متن کامل

Seasonal Variation in Eosinophil Count in Normal Healthy Adult Females

Background: Eosinophil count is influenced by variations in climate, culture, diet and life style. Moreover it fluctuates in a person with exercise and environmental stimuli, mainly seasonal allergen exposure. This study was conducted to know the effect of pollen peaks on eosinophil count in normal, non-allergic adult women. Material & Methods: This experimental study was carried out in Women M...

متن کامل

Lower airways inflammation in patients with ARDS measured using endotracheal aspirates: a pilot study

INTRODUCTION Our knowledge of acute respiratory distress syndrome (ARDS) pathogenesis is incomplete. The goal of this pilot study is to investigate the feasibility of measuring lower airways inflammation in patients with ARDS using repeated endotracheal aspirates (ETAs). METHODS ETAs were obtained within 24 hours by intensive care unit admission from 25 mechanically ventilated patients with A...

متن کامل

Fixation and Staining

mens from patients with Hodgkin's disease and five specimens from patients with reactive follicular hyperplasia. The use of chlorazol fast pink BK, a little known stain for eosinophil polymorphs, combined with image analysis facilitated rapid and reliable counting. Significant differences were found between the mean percentages of eosinophil polymorphs in the Rye subtypes of Hodgkin's disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 1952