Acute thrombus formation on phosphorilcholine surface modified flow diverters

نویسندگان

  • Miklos Marosfoi
  • Frederic Clarencon
  • Erin T Langan
  • Robert M King
  • Olivia W Brooks
  • Takamisu Tamura
  • John M Wainwright
  • Matthew J Gounis
  • Srinivasan Vedantham
  • Ajit S Puri
چکیده

PURPOSE Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. RESULTS Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p<0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). CONCLUSION In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vitro Evaluation of Intra-Aneurysmal, Flow-Diverter-Induced Thrombus Formation: A Feasibility Study.

BACKGROUND AND PURPOSE Intracranial aneurysm treatment by flow diverters aims at triggering intra-aneurysmal thrombosis. By combining in vitro blood experiments with particle imaging velocimetry measurements, we investigated the time-resolved thrombus formation triggered by flow diverters. MATERIALS AND METHODS Two test setups were built, 1 for particle imaging velocimetry and 1 for blood exp...

متن کامل

Topical Review Flow Diversion for Intracranial Aneurysms A Review

The introduction of flow diverters for treatment of intracranial aneurysms represents a major paradigm shift in the treatment of these lesions. The theoretical hallmark of flow diverters is the treatment of the diseased segment harboring the aneurysm instead of treating the aneurysm itself. Flow diverters are designed to induce disruption of flow near the aneurysm neck while preserving flow int...

متن کامل

Flow diversion for intracranial aneurysms: a review.

The introduction of flow diverters for treatment of intracranial aneurysms represents a major paradigm shift in the treatment of these lesions. The theoretical hallmark of flow diverters is the treatment of the diseased segment harboring the aneurysm instead of treating the aneurysm itself. Flow diverters are designed to induce disruption of flow near the aneurysm neck while preserving flow int...

متن کامل

Analysis of neointima development in flow diverters using optical coherence tomography imaging

BACKGROUND Flow diverters are used for the treatment of intracranial aneurysms. Surface modification may decrease the thrombogenicity of flow diverters but the details are unknown. Optical coherence tomography (OCT) is an intravascular imaging test with high resolution which identifies neointimal growth over stents. We compared the development of neointima in a flow diverter and stents with and...

متن کامل

Increased vascular wall thrombogenicity combined with reduced blood flow promotes occlusive thrombus formation in rabbit femoral artery.

OBJECTIVE Plaque disruption does not always result in complete thrombotic occlusion. The mechanism of arterial thrombus propagation remains unclear. METHODS AND RESULTS We studied how vascular wall thrombogenicity and blood flow reduction affect thrombus propagation using a rabbit model of single and repeated balloon injury. After balloon injury of the normal femoral artery, the blood flow wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018