Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model.

نویسندگان

  • Petr Ostadal
  • Mikulas Mlcek
  • Frantisek Holy
  • Svatava Horakova
  • Stepan Kralovec
  • Jan Skoda
  • Jan Petru
  • Andreas Kruger
  • Vladimir Hrachovina
  • Tomas Svoboda
  • Otomar Kittnar
  • Vivek Y Reddy
  • Petr Neuzil
چکیده

BACKGROUND Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS AND RESULTS Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. CONCLUSIONS Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Minimum Order Lumped-Parameter Model of Circulatory System for Patients with Suffered Left and Right-Sided Heart Failure

In this study a new minimum lumped electrical model of total circulatory system through numerical solutions to approximate the response of the human circulatory system was presented. Among five existent ventricular elastances as activity function of heart pumps, a more accurate model was chosen as well as the operation of baroreflex system to accommodate variations in heart rate and systemic va...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was...

متن کامل

Avoiding hemodynamic collapse during high-risk percutaneous coronary intervention: Advanced hemodynamics of impella support.

The rate of performing primary percutaneous coronary intervention in patients with complex coronary artery disease is increasing. The use of percutaneous mechanical circulatory support devices provides critical periprocedural hemodynamic support. Mechanical support has increased the safety and efficacy of interventional procedures in this high-risk patient population. Predicting patient respons...

متن کامل

A Practical Approach to Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention: An Interventional Perspective.

Percutaneous mechanical circulatory support has been used to stabilize patients in cardiogenic shock and provide hemodynamic support during high-risk percutaneous coronary interventions for several decades. The goal of this paper is to provide a practical approach to percutaneous mechanical circulatory support in patients undergoing percutaneous coronary intervention with cardiogenic shock and/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2012