The Noise Performance of Electron Multiplying Charge-Coupled Devices at soft X-ray energies

نویسندگان

  • James H. Tutt
  • Andrew D. Holland
  • Neil J. Murray
  • David J. Hall
  • Richard D. Harriss
  • Andrew Clarke
  • Anthony M. Evagora
چکیده

The use of EM-CCDs for high resolution soft Xray spectroscopy has been proposed in previous studies and the analysis that followed identified and verified experimentally a Modified Fano Factor for X-ray detection using an Fe X-ray source. However, further experiments with soft X-rays at 1000 eV were less successful, attributed to excessive split events. More recently, through the use of a deep depletion e2v CCD220 and on-chip binning, it was possible to greatly reduce the number of split events allowing the result for the Modified Fano Factor at soft X-ray energies to be verified. This paper looks at the earlier attempt to verify the Modified Fano Factor at 1000 eV with a e2v CCD97 and shows the issues created by the splitting of the charge cloud between pixels. It then compares these earlier results with new data collected using the e2v CCD220, investigating how split event reduction allows the Modified Fano Factor to be verified for low energy X-rays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of Electron-Multiplying CCDs for use on the International X-ray Observatory Off-Plane X-ray Grating Spectrometer

CCDs are regularly used as imaging and spectroscopic devices on space telescopes at X-ray energies due to their high quantum efficiency and linearity across the energy range. The International X-ray Observatory’s X-ray Grating Spectrometer will also look to make use of these devices across the energy band of 0.3 keV to 1 keV. At these energies, when photon counting, the charge generated in the ...

متن کامل

Improving the resolution in soft X-ray emission spectrometers through photon-counting using an Electron Multiplying CCD

In 2007, a study of back-illuminated Charge-Coupled Devices (CCDs) for soft Xray photon detection demonstrated the improvements that could be brought over more traditional micro-channel plate detectors for X-ray spectrometers based on diffraction gratings and position sensitive detectors. Whilst the spatial resolution was reported to be improved dramatically, an intrinsic limit of approximately...

متن کامل

Optimum Signal-to-noise Ratio Performance of Electron Multiplying Charge Coupled Devices

Electron multiplying charge coupled devices (EMCCDs) have revolutionized the world of low light imaging by introducing on-chip multiplication gain based on the impact ionization effect in the silicon. They combine the sub-electron readout noise with high frame rates. Signal-to-noise Ratio (SNR) is an important performance parameter for low-light-level imaging systems. This work investigates the...

متن کامل

Electron-multiplying CCDs for future soft X-ray spectrometers

CCDs have been used in several high resolution soft X-ray spectrometers for both space and terrestrial applications such as the Reflection Grating Spectrometer on XMM-Newton and the Super Advanced X-ray Emission Spectrometer at the Paul Scherrer Institut in Switzerland. However, with their ability to use multiplication gain to amplify signal and suppress readout noise, EM-CCDs are being conside...

متن کامل

Low Voltage Electron Multiplying CCD in a CMOS Process

Low light level and high-speed image sensors as required for space applications can suffer from a decrease in the signal to noise ratio (SNR) due to the photon-starved environment and limitations of the sensor’s readout noise. The SNR can be increased by the implementation of Time Delay Integration (TDI) as it allows photoelectrons from multiple exposures to be summed in the charge domain with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012