Phosphene thresholds elicited by transcorneal electrical stimulation in healthy subjects and patients with retinal diseases.
نویسندگان
چکیده
PURPOSE To evaluate electrically evoked phosphene thresholds (EPTs) in healthy subjects and in patients with retinal disease and to assess repeatability and possible correlations with common ophthalmologic tests. METHODS In all, 117 individuals participated: healthy subjects (n = 20) and patients with retinitis pigmentosa (RP, n = 30), Stargardt's disease (STG, n = 14), retinal artery occlusion (RAO, n = 20), nonarteritic anterior ischemic optic neuropathy (NAION, n = 16), and primary open-angle glaucoma (POAG, n = 17). EPTs were determined at 3, 6, 9, 20, 40, 60, and 80 Hz with 5 + 5-ms biphasic current pulses using DTL electrodes. Subjects were examined twice (test-retest range: 1-6 weeks). An empirical model was developed to describe the current-frequency relationship of EPTs. Visual acuity, visual field (kinetic + static), electrophysiology (RP, RAO, STG: Ganzfeld-electroretinography [ERG]/multifocal-ERG; POAG: pattern-ERG; NAION: VEP), slit-lamp biomicroscopy, fundus examination, and tonometry were assessed. RESULTS EPTS varied between disease groups (20 HZ: healthy subjects: 0.062 ± 0.038 mA; STG: 0.102 ± 0.097 mA; POAG: 0.127 ± 0.09 mA; NAION: 0.244 ± 0.126 mA; RP: 0.371 ± 0.223 mA; RAO: 0.988 ± 1.142 mA). In all groups EPTs were lowest at 20 Hz. In patients with retinal diseases and across all frequencies EPTs were significantly higher than those in healthy subjects, except in STG at 20 Hz (P = 0.09) and 40 Hz (P = 0.17). Test-retest difference at 20 Hz was 0.006 mA in the healthy group and 0.003-0.04 mA in disease groups. CONCLUSIONS Considering the fast, safe, and reliable practicability of EPT testing, this test might be used more often under clinical circumstances. Determination of EPTs could be potentially useful in elucidation of the progress of ophthalmologic diseases, either in addition to standard clinical assessment or under conditions in which these standard tests cannot be used meaningfully. (ClinicalTrials.gov number, NCT00804102.).
منابع مشابه
Visual Neuroscience Optical Imaging of Visual Cortical Responses Evoked by Transcorneal Electrical Stimulation With Different Parameters
Citation: Ma Z, Cao P, Sun P, et al. Optical imaging of visual cortical responses evoked by transcorneal electrical stimulation with different parameters. Invest Ophthalmol Vis Sci. 2014;55:5320–5331. DOI: 10.1167/iovs.14-14600 PURPOSE. The use of phosphenes evoked by transcorneal electrical stimulation (TcES) has been proposed as a means of residual visual function evaluation and candidate sel...
متن کاملRetinal ganglion cell response properties in the transcorneal electrically evoked response of the visual system
To identify the retinal origin of a cortical evoked potential elicited by transcorneal electrical stimulation of the visual system (EER), the response properties of retinal ganglion cells (RGCs) of cats to transcorneal electrical stimuli were studied. The discharge latency of RGCs to transcorneal stimulation had two peaks with a high temporal resolution. The latency of early components of the E...
متن کاملChronic intravitreous infusion of ciliary neurotrophic factor modulates electrical retinal stimulation thresholds in the RCS rat.
PURPOSE To determine whether the sustained intravitreous delivery of CNTF modulates cortical response thresholds to electrical retinal stimulation in the RCS rat model of retinal degeneration. METHODS Animals were assigned to four groups: untreated, nonsurgical control and infusion groups of 10 ng/d CNTF, 1 ng/d CNTF, and PBS vehicle control. Thresholds for electrically evoked cortical potent...
متن کاملTranscorneal Electrical Stimulation in Patients with Retinal Artery Occlusion: A Prospective, Randomized, Sham-Controlled Pilot Study
INTRODUCTION The purpose of this study was to investigate the safety and efficacy of transcorneal electrical stimulation (TES) in patients suffering from retinal artery occlusion (RAO). METHODS Twelve patients with central and one patient with branch RAO (age 25-84 years, median 74 years) were enrolled in this prospective, randomized, sham-controlled study. RAO was diagnosed 10 days to 17 mon...
متن کاملThe Comparison of Tooth Pulp Electrical Threshold in Patients with Type II Uncontrolled Diabetes and Healthy Subject
Objective: Diabetic patients suffer from different types of complications associated with peripheral nerves. A clear manifestation of these complications is found in the mouth where neuropathies commonly occur. The measurement of electrical stimulation threshold of teeth signifies premature involvement of peripheral nerves in the teeth. The aim of present study is to compare pulp tester respons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 53 12 شماره
صفحات -
تاریخ انتشار 2012