Voltage Stability Improvement using STATCOM and SVC

نویسندگان

  • Anwar S. Siddiqui
  • Tanmoy Deb
چکیده

Voltage stability of a system is affected by reactive power limit of the system. FACTs devices improve the reactive power flow in system thereby improving voltage stability. This paper explores the effect of SVC and STATCOM on static voltage stability. IEEE14 bus system has been used to demonstrate the ability of SVC and STATCOM in improving the voltage stability margin. These FACTs controllers help to increase the load ability margin of the power network.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of SVC and STATCOM in Static Voltage Stability Margin Enhancement

One of the major causes of voltage instability is the reactive power limit of the system. Improving the system's reactive power handling capacity via Flexible AC transmission System (FACTS) devices is a remedy for prevention of voltage instability and hence voltage collapse. In this paper, the effects of SVC and STATCOM in Static Voltage Stability Margin Enhancement will be studied. AC and DC r...

متن کامل

A Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data

Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...

متن کامل

Comparison of FACTS Devices for Two Area Power System Stability Enhancement using MATLAB Modelling

Received Mar 2, 2014 Revised Jul 10, 2014 Accepted Jul 3, 2014 Modern Power Transmission networks are becoming increasingly stressed due to growing demand and restrictions on building new lines. Losing stability is one of the major threat of such a stressed system following a disturbance. Flexible ac transmission system (FACTS) devices are found to be very effective in a transmission network fo...

متن کامل

Simultaneous RPD and SVC Placement in Power Systems for Voltage Stability Improvement Using a Fuzzy Weighted Seeker Optimization Algorithm

Voltage stability issues are growing challenges in many modern power systems. This paper proposes optimizing the size and location of Static VAR Compensator (SVC) devices using a Fuzzy Weighted Seeker Optimization Algorithm (FWSOA), as an effective solution to overcome such issues. Although the primary purpose of SVC is bus voltage regulation, it can also be useful for voltage stability enhance...

متن کامل

Analysis and Impact of D-STATCOM, Static Var Compensator, Fuzzy Based SVC Controller on the Stability of a Wind Farm

Received Jan 18, 2017 Revised Mar 18, 2017 Accepted Apr 2, 2017 In recent years, applications of facts systems have been developed for the compensation of active and reactive power. Facts systems are electronics devices that are connected to the wind farm. This paper presents the impacts of some of these devices on the stability of a wind farm, especially D-STATCOM, Static Var Compensator and F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014