Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study
نویسندگان
چکیده
BACKGROUND The Streamlined Liner of the Pharynx Airway (SLIPA), a type of supraglottic airway, has a non-inflatable cuff that softens at body temperature to fit the laryngeal structure. We investigated whether pre-warming of SLIPA to body temperature may improve insertion parameters. METHODS Ninety adult patients were assigned equally randomized to either Group W or Group R. Anesthesia was induced using propofol, fentanyl, and rocuronium. In Group W, the SLIPA was warmed to 37 ° C before insertion, whereas in Group R, it was inserted at room temperature. The insertion time, oropharyngeal leak pressure, postoperative throat pain, blood staining, regurgitation, number of attempts at insertion, and difficulty of insertion were compared between the two groups. RESULTS The insertion time was shorter in Group W than in Group R (3.60 [3.15-4.06] s vs. 6.00 [4.45-7.50] s; P < 0.001). Oropharyngeal leak pressure from the time of insertion until 3 min after insertion was significantly higher in Group W than in Group R (P < 0.05). Postoperative throat pain, measured using the visual analog scale, was lower in Group W than in Group R (0.00 [0.00-2.50] vs. 2.00 [0.00-4.50]; P = 0.006). The difficulty of insertion was lower in Group W than in Group R (P < 0.004). There were no significant differences in terms of blood staining, regurgitation, and number of attempts. CONCLUSIONS Pre-warming the SLIPA to body temperature has significant benefits compared to maintaining the device at room temperature. Specifically, insertion was easier, both insertion and fitting to the laryngeal structure could be performed more quickly, and the incidence of sore throat was reduced. TRIAL REGISTRATION Clinical Research Information Identifier NCT01209000.
منابع مشابه
Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPATM) improves fitting to the laryngeal structure: a randomized, double-blind study
Background: The Streamlined Liner of the Pharynx Airway (SLIPA), a type of supraglottic airway, has a non-inflatable cuff that softens at body temperature to fit the laryngeal structure. We investigated whether pre-warming of SLIPA to body temperature may improve insertion parameters. Methods: Ninety adult patients were assigned equally randomized to either Group W or Group R. Anesthesia was in...
متن کاملComparison of the clinical effectiveness between the streamlined liner of pharyngeal airway (SLIPA) and the laryngeal mask airway by novice personnel
BACKGROUND The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA) with the classic laryngeal mask airway when used by novice personnel. METHODS There were 114 patients enrolled into this study who underwent general anesthesia were randomly allocated into one of 2 groups; LMA group (n = 57) or SLIPA group (n = 57). After insertion, insertion success rate, inse...
متن کاملComparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.
Introduction. This study compared streamlined liner of the pharynx airway (SLIPA) and I-gel noninflatable, single-use, supraglottic airway device (SAD) performance in anesthetized, paralyzed adults. Methods. Eighty adults (ASA physical statuses I-III) who were undergoing elective procedures under general anesthesia with an SAD were enrolled in this prospective, randomized, single-blind study. S...
متن کاملThe clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA™) compared with the laryngeal mask airway ProSeal™ during general anesthesia
BACKGROUND The aim of this study was to compare the streamlined liner of the pharynx airway (SLIPA), a new supraglottic airway device (SGA), with the laryngeal mask airway ProSeal (PLMA) during general anesthesia. METHODS Sixty patients were randomly allocated to two groups; a PLMA group (n = 30) or a SLIPA group (n = 30). Ease of use, first insertion success rate, hemodynamic responses to in...
متن کاملBrief review: the Cobra Perilaryngeal Airway (CobraPLA and the Streamlined Liner of Pharyngeal Airway (SLIPA) supraglottic airways.
PURPOSE To summarize the published literature related to two, new supraglottic airways (SGAs): the Cobra Perilaryngeal Airway (CobraPLA) and the Streamlined Liner of Pharyngeal Airway (SLIPA). SOURCE We identified original articles, through searches on Medline and PubMed, using the keywords 'Cobra', 'CobraPLA', 'Cobra-PLA', 'PLA', and 'SLIPA'. PRINCIPAL FINDINGS Searches identified 28 publi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2015