Upcoming Methods and Specifications of Continuous Intraocular Pressure Monitoring Systems for Glaucoma

نویسندگان

  • Amir Molaei
  • Vahid Karamzadeh
  • Sare Safi
  • Hamed Esfandiari
  • Javad Dargahi
  • Mohammad Azam Khosravi
چکیده

Glaucoma is the leading cause of irreversible blindness and vision loss in the world. Although intraocular pressure (IOP) is no longer considered the only risk factor for glaucoma, it is still the most important one. In most cases, high IOP is secondary to trabecular meshwork dysfunction. High IOP leads to compaction of the lamina cribrosa and subsequent damage to retinal ganglion cell axons. Damage to the optic nerve head is evident on funduscopy as posterior bowing of the lamina cribrosa and increased cupping. Currently, the only documented method to slow or halt the progression of this disease is to decrease the IOP; hence, accurate IOP measurement is crucial not only for diagnosis, but also for the management. Due to the dynamic nature and fluctuation of the IOP, a single clinical measurement is not a reliable indicator of diurnal IOP; it requires 24-hour monitoring methods. Technological advances in microelectromechanical systems and microfluidics provide a promising solution for the effective measurement of IOP. This paper provides a broad overview of the upcoming technologies to be used for continuous IOP monitoring.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What is the Real Cause of Glaucoma?

Introduction: The term glaucoma refers to a group of diseases that have a characteristic optic neuropathy with associated visual field loss in common. Intraocular pressure has been considered to be the only causal factor for glaucoma and the only factor that can be manipulated to alter the course of the disease. But considering high intraocular pressure as the only factor responsible for glauco...

متن کامل

Evaluation of various factors relating to intraocular pressure and C/D ratio

Introduction: Intraocular pressure (IOP) is determined by three factors: the rate of aqueous humor production by the ciliary’s body, the resistances to aqueous out flow across the trabecular meshwork and the level of episcleral vessel pressure. IOP varies with a number of factors, including: age, sex, race, systemic disease and diurnal variation. The purpose of this study is measurement of IO...

متن کامل

[Sensimed Triggerfish(®) as a new system for continuous recording of 24-hour intraocular pressure in glaucoma patients].

Recent technological developments have provided a tool for continuous intraocular pressure (IOP) monitoring for a period of up to 24 h in patients with open angle glaucoma.1 We have taken part in a randomized clinical trial in which 8 patients received continuous IOP monitoring for 24 h with hospital admittance. The inclusion criteria were having an age comprised between 18 and 85 years with si...

متن کامل

Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.

OBJECTIVE To examine the safety, tolerability, and reproducibility of intraocular pressure (IOP) patterns during repeated continuous 24-hour IOP monitoring with a contact lens sensor. METHODS Forty patients suspected of having glaucoma(n=21) or with established glaucoma (n=19) were studied.Patients participated in two 24-hour IOP monitoring sessions (S1 and S2) at a 1-week interval (SENSIMED ...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018