The truncation artefact in patients with a high body mass index on myocardial perfusion SPECT.

نویسندگان

  • Naoya Matsumoto
  • Yasuyuki Suzuki
  • Shunichi Yoda
  • Atsushi Hirayama
چکیده

To cite: Matsumoto N, Suzuki Y, Yoda S, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014205407 DESCRIPTION Recognition of the truncation artefact is important for the control of image quality on myocardial perfusion images in single-photon emission CT (SPECT). Truncation artefact is usually seen in obese patients who may deviate from a γ-ray detector field. The deviation of the body in the limited detector field sometimes causes the truncation of the left ventricle and low image quality. We encountered the truncation artefact in patients with a high body mass index (34.2) which raises the possibility of an unusual detector arc in the non-circular detector orbit. Figure 1A depicts a presence of the truncation of the detector field in the 29th projection without the truncation of the left ventricle. Figure 1B does not show the truncation of the detector field in the same 29th projection after the optimisation of the patient’s body location. This type of ‘field truncation’ causes the low image quality in the corresponding reconstructed short-axis siles (figure 2A); with the field truncation. Figure 2B without the field truncation shows normal perfusion image. The presence of truncation artefact can be recognised by following two methods. First is the presence of ununiformity of the raw projection field (figure 1A), second is

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The truncation artifact in a skinny patient following myocardial perfusion SPECT

Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...

متن کامل

Correlation of myocardial Tc 99m-MIBI perfusion SPECT with coronary angiography in Namazi Hospital/Shiraz/Iran [Persian]

Coronary heart disease (CAD) is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of CAD and is suggested by many investigators in recent years. In this study, 64 patients wh...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMJ case reports

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014