Evaluation of the Performance of a Micromethod for Measuring Urinary Iodine by Using Six Sigma Quality Metrics

نویسندگان

  • Husniza Hussain
  • Norhayati Mustafa Khalid
  • Rusidah Selamat
  • Wan Mohamud Wan Nazaimoon
چکیده

BACKGROUND The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. METHODS UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TEas) set by two external quality assurance (EQA) providers. RESULTS UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TEas showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TEcalc)<total allowable error (TEa) for the low concentration level; all laboratories showed an acceptable performance for the medium-high level, and two laboratories showed an acceptable performance for the high level. When calculated against the Ensuring the Quality of UI Procedures (EQUIP) TEas, the performance of all laboratories was≤2.49 Sigma metrics at all concentrations. Only one laboratory had TEcalc<TEa for the medium-high and high concentrations. CONCLUSIONS UIMM showed unacceptable performance for the iodine deficiency levels and variable performance at other concentrations according to different TEas.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Assessment of Analytical Phase Quality of Clinical Biochemistry Parameters Using Sigma Metrics

Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemist...

متن کامل

Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?

Background: Clinical application of the test results are profoundly influenced by laboratory errors. Nowadays, the best way to evaluate the performance of a method is to determine its sigma scale according to total allowable error (TEa) and analytical errors, including random and systematic errors. In this study, the performance of the measuring kits for biochemical analytes belonging to Pars A...

متن کامل

Evaluation of the Client Patients Waiting Time in Referral Restorative Dentistry Department of Dental Clinic Using Six Sigma Model

Introduction: Waiting time is one of the factors affecting patients' satisfaction with the quality of services, therefore, reducing the waiting time has an essential role in the improvement of services and clients' satisfaction. The present study was performed to study the client patients waiting time in referral restorative dentistry department of dental clinic using Six Sigma model. Method: I...

متن کامل

Evaluation of the Client Patients Waiting Time in Referral Restorative Dentistry Department of Dental Clinic Using Six Sigma Model

Introduction: Waiting time is one of the factors affecting patients' satisfaction with the quality of services, therefore, reducing the waiting time has an essential role in the improvement of services and clients' satisfaction. The present study was performed to study the client patients waiting time in referral restorative dentistry department of dental clinic using Six Sigma model. Method: I...

متن کامل

Mistake Proofing Cam Mechanism Through Six-sigma Process: Case Study on Clothes Printing Machines

Controlling the occurrence of defects is a major challenge for manufacturing organizations that are seeking to enhance their competitive position in today’s global market. This paper considers the process of screen-printing T-shirts using hydraulic and pneumatic printing machines. Several defects in the output of this printing process have been observed, especially with multi colors printing as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2013