Advanced interferometric phase and amplitude noise measurements

نویسندگان

  • Enrico Rubiola
  • Vincent Giordano
چکیده

The measurement of the close-to-the-carrier noise of two-port radio frequency and microwave devices is a relevant issue in time and frequency metrology and in some fields of electronics, physics, and optics. While phase noise is the main concern, amplitude noise is often of interest. Presently the highest sensitivity is achieved with the interferometric method, that consists of the amplification and synchronous detection of the noise sidebands after suppressing the carrier by vector subtraction of an equal signal. A substantial progress in understanding the flicker noise mechanism of the interferometer results in new schemes that improve by 20–30 dB the sensitivity at low Fourier frequencies. These schemes, based on two or three nested interferometers and vector detection of noise, also feature closed-loop carrier suppression control, simplified calibration, and intrinsically high immunity to mechanical vibrations. This article provides the complete theory and detailed design criteria, and reports on the implementation of a prototype working at the carrier frequency of 100 MHz. In real-time measurements, a background noise of 2175 to 2180 dBrad/Hz has been obtained at f 51 Hz off the carrier; the white noise floor is limited by the thermal energy kBT0 referred to the carrier power P0 and by the noise figure of an amplifier. Exploiting correlation and averaging in similar conditions, the sensitivity exceeds 2185 dBrad/Hz at f 51 Hz; the white noise floor is limited by thermal uniformity rather than by the absolute temperature. A residual noise of 2203 dBrad/Hz at f 5250 Hz off the carrier has been obtained, while the ultimate noise floor is still limited by the averaging capability of the correlator. This is equivalent to a signal-to-noise ~S/N! ratio of 2310 with a frequency spacing of 2.5310. All these results have been obtained in a relatively unclean electromagnetic environment, and without using a shielded chamber. Implementation and experiments at that sensitivity level require skill and tricks, for which a great effort is spent in the article. Applications include the measurement of the properties of materials and the observation of weak flicker-type physical phenomena, out of reach for other instruments. As an example, we measured the flicker noise of a by-step attenuator (2171 dBrad/Hz at f 51 Hz! and of the ferrite noise of a reactive power divider (2173.7 dBrad/Hz at f 51 Hz! without need of correlation. In addition, the real-time measurements can be exploited for the dynamical noise correction of ultrastable oscillators. © 2002 American Institute of Physics. @DOI: 10.1063/1.1480458#

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Method of Filtering and Unwrapping SAR Interferometric Phase Based on Nonlinear Phase Model

This paper presents a new efficient algorithm of filtering and unwrapping phase images for interferometric synthetic aperture radar (InSAR) based on nonlinear phase model. First, we analyzed the statistical and signal properties of interferometric phase, and proposed the concept of nonlinear phase model. The model of reflecting topographic contour is used to approximate the interferometric phas...

متن کامل

Ultrashort Optical Pulse Measurements by Inteferometric Spectrogram

We experimentally demonstrate that an interferometric spectrogram of the signal pulse can be processed differently to obtain the spectral amplitude and(or) phase profile(s). Consistency between the results obtained by frequencyresolved optical gating (FROG) and modified interferometric field autocorrelation (MIFA) methods is confirmed. We also show that the robustness of MIFA technique against ...

متن کامل

Very high frequency and microwave interferometric phase and amplitude noise measurements

The interferometric technique allows close-to-the-carrier measurements of both phase and amplitude noise, improving the instrument noise floor by 10–25 dB as compared to the traditional method based on a saturated mixer. Principles and basic equations describing the noise measurement system are given, together with design strategies suitable to microwave and very high frequency bands. Two proto...

متن کامل

Advanced bridge (interferometric) phase and amplitude noise measurements

The measurement of the close-to-the-carrier noise of two-port radiofrequency and microwave devices is a relevant issue in time and frequency metrology and in some fields of electronics, physics and optics. While phase noise is the main concern, amplitude noise is often of interest. Presently the highest sensitivity is achieved with the interferometric method, that consists of the amplification ...

متن کامل

Benefits of Artificially Generated Gravity Gradients for Interferometric Gravitational-Wave Detectors

We present an approach to experimentally evaluate gravity gradient noise, a potentially limiting noise source in advanced interferometric gravitational wave (GW) detectors. In addition, the method can be used to provide sub-percent calibration in phase and amplitude of modern interferometric GW detectors. Knowledge of calibration to such certainties shall enhance the scientific output of the in...

متن کامل

Interferometric SAR data filtering based on amplitude optimization

In this paper, a methodology of noise reduction for interferometric SAR data is proposed based on amplitude optimization model. From the relationship between the amplitude and phase of complex signal, the optimal parameter vector of the filter is constructed pixel by pixel to maximize the minor amplitude of two coherent interferometric signals. The filter is implemented on the complex signal do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002