Error Model and Accuracy Calibration of 5-Axis Machine Tool
نویسندگان
چکیده
To improve the machining precision and reduce the geometric errors for 5-axis machinetool, error model and calibration are presented in this paper. Error model is realized by the theory of multi-body system and characteristic matrixes, which can establish the relationship between the cutting tool and the workpiece in theory. The accuracy calibration was difficult to achieve, but by a laser approach-laser interferometer and laser tracker, the errors can be displayed accurately which is benefit for later compensation.
منابع مشابه
Magnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملReal Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation
Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...
متن کاملMeasurement of Volumetric Positioning Accuracy of a 5-axis Machine By Laser Vector Technique
For a 5-axis machine tool, the 3D volumetric tool-tip positioning accuracy is very important for parts accuracy and quality assurance. Just calibrate the 3 linear axes and the 2 rotational axes is not enough. There are straightness errors for each of the 3 linear axes, and squareness errors between the 3 linear axes, misalignment errors between the linear axes and the rotary axes. Hence, it is ...
متن کاملMeasurement of Error motions on Five-axis Machine Tools by Ball Bar Tests
The inclusion of the application of the double ball bar (DBB) measurement to the accuracy calibration of five-axis machine tools into the revision of ISO standards is currently under the discussion. This paper presents the modified DBB measurement device, referred to as “DBB5” in our study, where master balls are supported from the 45 ° direction to the spindle axis. It can perform all the circ...
متن کاملDevelopment of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection
The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -