Sequential injection analysis for Cr(VI) and Cr(III) with renewable surface reflection spectrophotometry.

نویسندگان

  • Jianya Wang
  • Bin Xue
چکیده

On the basis of the chromogenic reaction of chromium(VI) with 1,5-diphenylcarbohydrazide (DPC) on the surface of Polysorb C-18 beads and the sequential injection renewable surface technique (SI-RST), a highly sensitive reflect spectrophotometric method for the determination of chromium(III) and chromium(VI) was proposed. Considerations of system and flow cell design, and factors that influence the determination performance were discussed. With 300 microl of sample loaded and 0.6 mg of beads trapped, the linear response range was 0.02 - 0.5 mg l(-1) Cr(VI) with a detection limit (3 sigma) of 2.4 microg l(-1) Cr(VI). The method achieves a precision of 1.3% RSD (n = 11) and a throughput of 53 samples per hour. The determination of Cr(III) was based on the same reaction for the determination of Cr(VI) after being oxidized by (NH4)2S2O8. The precision of the oxidation method was evaluated using a 0.2 mg l(-1) Cr(III) standard, yielding an RSD of 2.5% (n = 11). The average recovery of Cr(III) oxidized was tested to be 99.1%. The proposed method was used in the simultaneous determination of Cr(VI) and Cr(III) in water samples, and the error was less than 3%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line electrochemical oxidation of Cr(III) for the determination of total Cr by flow injection-solid phase spectrophotometry.

A novel on-line oxidation method of ultra-trace Cr(III) dissolved in natural water has been developed using a flow electrolysis cell. This method was successfully applied to the determination of the total Cr concentration by flow injection-solid phase spectrophotometry using diphenylcarbazide as a coloring agent. With the applied potential of 1.35 V (vs. Ag/AgCl) and the flow rate of 0.80 cm(3)...

متن کامل

Automation of liquid-liquid extraction-spectrophotometry using prolonged pseudo-liquid drops and handheld CCD for speciation of Cr(VI) and Cr(III) in water samples.

A simple spectrophotometric system, based on a prolonged pseudo-liquid drop device as an optical cell and a handheld charge coupled device (CCD) as a detector, was constructed for automatic liquid-liquid extraction and spectrophotometric speciation of trace Cr(VI) and Cr(III) in water samples. A tungsten halogen lamp was used as the light source, and a laboratory-constructed T-tube with two ope...

متن کامل

Extraction of Polystyrene from Styrofoam Waste: Synthesis of Novel Chelating Resin for the Enrichment and Speciation of Cr(III)/Cr(VI) Ions in Industrial Effluents

Polystyrene (PS) was extracted from Styrofoam (expanded polystyrene foam) waste, so called white pollutant. The PS was functionalized with N,NBis(2-aminobenzylidene)benzene-1,2diamine (ABA) ligand through an azo spacer. The resin was characterized by FT-IR spectroscopy and elemental analysis. The PSN=N-ABA resin was used for the enrichment and speciation of Cr(III)/Cr(VI) ions and total Cr dete...

متن کامل

Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents

Simple and robust analytical procedures were developed for hexavalent chromium (Cr(VI)) and lead (Pb(II)) by dispersive liquid-liquid microextraction (DLLME) using microsample injection system coupled with flame atomic absorption spectrophotometry (MIS-FAAS). For the current study, ammonium pyrrolidine dithiocarbamate (APDC), carbon tetrachloride, and ethanol were used as chelating agent, extra...

متن کامل

Selective colorimetric detection of Cr(iii) and Cr(vi) using gallic acid capped gold nanoparticles.

A colorimetric assay is proposed for the selective detection of Cr(iii) and Cr(vi) via the aggregation-induced color change of gallic acid capped gold nanoparticles (GA-AuNPs). The AuNPs are characterized using UV-vis spectroscopy, transmission electron microscopy (TEM), dynamic light scattering (DLS) and Fourier-transform infrared spectrometry (FT-IR). To detect Cr(iii) and Cr(vi) coexisting i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 2006