Evaluation of the left atrial appendage with real-time 3-dimensional transesophageal echocardiography: implications for catheter-based left atrial appendage closure.

نویسندگان

  • Gaetano Nucifora
  • Francesco F Faletra
  • François Regoli
  • Elena Pasotti
  • Giovanni Pedrazzini
  • Tiziano Moccetti
  • Angelo Auricchio
چکیده

BACKGROUND Precise knowledge of left atrial appendage (LAA) orifice size is crucial for correct sizing of LAA closure devices. The aim of the present study was to determine the performance of real-time 3D transesophageal echocardiography (RT3DTEE) for LAA orifice size assessment, compared with 2D transesophageal echocardiography (2DTEE), and to investigate the impact of atrial fibrillation (AF) on LAA orifice size. METHODS AND RESULTS One hundred thirty-seven patients (38 control subjects, 31 with paroxysmal AF, 38 with persistent AF and 30 with permanent AF) underwent 2DTEE and RT3DTEE. Both techniques were used to measure LAA orifice area. Clinically-indicated 64-slice computed tomography (CT) was used as reference technique in 46 patients. Two-dimensional TEE underestimated LAA orifice area, compared with RT3DTEE (1.99±0.94 cm(2) versus 3.05±1.27 cm(2); P<0.001). RT3DTEE showed higher correlation with CT for the assessment of LAA orifice area, compared with 2DTEE (r=0.92; 95% confidence interval, 0.85 to 0.95, versus r=0.72; 95% confidence interval, 0.54 to 0.83, respectively). At Bland-Altman analysis, RT3DTEE and 2DTEE underestimated LAA orifice area, compared with CT. However, RT3DTEE showed smaller bias (0.07 cm(2) versus 0.72 cm(2)) and narrower limits of agreement (-0.71 to 0.85 cm(2) versus -0.58 to 2.02 cm(2)) with CT, compared with 2DTEE. Among AF patients, a progressive increase in RT3DTEE-derived LAA orifice area was observed with increasing frequency of AF (P<0.001). At multivariate analysis, AF and left atrial volume index (P<0.001 for both) were independently associated with RT3DTEE-derived LAA orifice area. CONCLUSIONS RT3DTEE is more accurate than 2DTEE for the assessment of LAA orifice size. A progressive increase in LAA orifice area is observed with increasing frequency of AF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left Atrial Appendage Closure Under Intracardiac Echocardiographic Guidance: Feasibility and Comparison With Transesophageal Echocardiography

BACKGROUND Transcatheter left atrial appendage closure is an alternative therapy for stroke prevention in atrial fibrillation patients. These procedures are currently guided with transesophageal echocardiography and fluoroscopy in most centers. As intracardiac echocardiography (ICE) is commonly used in other catheter-based procedures, we sought to determine the safety and effectiveness of intra...

متن کامل

Segmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network

Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...

متن کامل

Evaluation of the Left Atrial Appendage with Real-Time Three-Dimensional Transesophageal Echocardiography: Implications For Catheter-Based Left Atrial Appendage Closure Nucifora et al: RT3DTEE Imaging of LAA

Background Precise knowledge of left atrial appendage (LAA) orifice size is crucial for correct sizing of LAA closure devices. Aim of the present study was to determine the performance of real-time three-dimensional transesophageal echocardiography (RT3DTEE) for LAA orifice size assessment, compared to twodimensional transesophageal echocardiography (2DTEE), and to investigate the impact of atr...

متن کامل

Segmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network

Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...

متن کامل

Real-time 3-dimensional transesophageal echocardiography during left atrial radiofrequency catheter ablation for atrial fibrillation.

Left atrial radiofrequency catheter ablation has been recognized as an important treatment option for drugrefractory symptomatic atrial fibrillation.1 Recent consensus on technique favors catheter ablation directed to the left atrium near the pulmonary vein (PV) ostium to achieve PV isolation.2 However, ablation in the region of the ligament of Marshall (LOM) to achieve electrical isolation of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 2011