Electrogenerated chemiluminescence derivatization reagents for carboxylic acids and amines in high-performance liquid chromatography using tris(2,2'-bipyridine)ruthenium(II).

نویسندگان

  • Hirotoshi Morita
  • Masaharu Konishi
چکیده

2-(2-Aminoethyl)-1-methylpyrrolidine and N-(3-aminopropyl)pyrrolidine (NAPP) were found to be selective and sensitive derivatization reagents for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and ibuprofen were used as model compounds of carboxylic acids, and the derivatization conditions were optimized with myristic acid as a representative of free fatty acids. All the fatty acids tested were reacted with NAPP to produce highly sensitive derivatives under the mild reaction conditions of room temperature for 30 min in acetonitrile containing 2-bromo-1-ethylpyridinium tetrafluoroborate and 9-methyl-3,4-dihydro-2H-pyrido[1,2-a]pyrimidin-2-one. The chemiluminescence intensities were similar for all fatty acids. The derivatives obtained from 10 free fatty acids were completely separated by reversed-phase chromatography under isocratic elution conditions. The on-column detection limits (signal-to-noise ratio of 3) with proposed HPLC separation and chemiluminescence detection were 70 and 45 fmol for myristic acid and ibuprofen, respectively. The free fatty acids in human plasma were successfully determined using the present method. Histamine, a model compound of primary amines, was also determined after precolumn derivatization with 3-(diethylamino)propionic acid at room temperature for 60 min in acetonitrile containing N,N'-dicyclohexylcarbodiimide and 3,4-dihydro-3-hydroxy-4-oxo-1,2,3-benzotriazine with the detection limit of 70 fmol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitive determination of domoic acid using high-performance liquid chromatography with electrogenerated tris(2,2'-bipyridine)ruthenium(III) chemiluminescence detection.

A new sensitive determination method of domoic acid based on the chemiluminescent reaction of tris(2,2'-bipyridine)ruthenium(III) has been developed. The method exhibited good reproducibility. The relative standard deviation of six replicate measurements was 1.6% for 10 ng ml(-1). A calibration graph, based on a standard domoic acid solution, was linear over the range of 1 - 500 ng ml(-1) (coef...

متن کامل

Electrogenerated chemiluminescence (ECL) 79. Reductive-oxidation ECL of tris(2,2′-bipyridine)ruthenium(II) using hydrogen peroxide as a coreactant in pH 7.5 phosphate buffer solution

Hydrogen peroxide (H2O2) can be used as a coreactant to generate reductive-oxidation ECL of Tris(2,2′-bipyridine)ruthenium(II), Ru(bpy)3 (bpy = 2,2′-bipyridine), in pH 7.5 phosphate buffer solution (PBS). Although Ru(bpy)3 is adsorbed and precipitated on the electrode upon reduction of Ru(bpy)3 in aqueous solutions, ECL can still be generated and scanning electrochemical microscopy (SECM) e r o...

متن کامل

Considering the chemical energy requirements of the tri-n-propylamine co-reactant pathways for the judicious design of new electrogenerated chemiluminescence detection systems.

The introduction of a 'co-reactant' was a critical step in the evolution of electrogenerated chemiluminescence (ECL) from a laboratory curiosity to a widely utilised detection system. In conjunction with a suitable electrochemiluminophore, the co-reactant enables generation of both the oxidised and reduced precursors to the emitting species at a single electrode potential, under the aqueous con...

متن کامل

Electrochemiluminescence Detection of Primary Amines Using Tris(bipyridine)ruthenium(III) after Derivatization with Divinylsulfone

Aliphatic primary amines are industrial chemicals with a wide variety of applications. For the determination of these substances, HPLC has recently been used; it has several advantages over other analytical methods, including high selectivity and sensitivity. On the other hand, an electrochemiluminescence (ECL) method has been developed as a highly sensitive method for HPLC detection.)-3 Howeve...

متن کامل

Column-switching HPLC determination of mexiletine using tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence and precolumn derivatization with divinylsulfone.

A sensitive HPLC method combined with a column-switching system and tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence (ECL) detection has been developed for the quantitative determination of mexiletine (MEX). MEX was derivatized by divinylsulfone (DVS) and then measured. The optimum conditions for the derivatization reaction were 10 µL of sample solutions, 40 mM DVS (pH 8.0), a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 7  شماره 

صفحات  -

تاریخ انتشار 2002