MR-based and Optical Prospective Motion Correction for High Resolution DWI with RS-EPI
نویسندگان
چکیده
Introduction: Recently, multiple approaches have been proposed to perform motion correction for diffusion imaging using optical tracking with cameras [1,2] or using MR-based methods which perform real-time registration between volumes [3-5]. In this study, we demonstrate the application of and compare both optical and MR-based motion correction to high-resolution diffusion-weighted imaging using readout-segmented EPI (RS-EPI).
منابع مشابه
Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.
Diffusion-weighted imaging (DWI) obtained with interleaved echo-planar imaging (EPI) pulse sequence has great potential of characterizing brain tissue properties at high spatial-resolution. However, interleaved EPI based DWI data may be corrupted by various types of aliasing artifacts. First, inconsistencies in k-space data obtained with opposite readout gradient polarities result in Nyquist ar...
متن کاملHigh-Resolution Diffusion-Weighted Imaging of the Orbits Using Readout-Segmented EPI
Introduction: Diffusion-weighted MRI (DWI) has demonstrated great value for the diagnostic workup of acute ischemic stroke and other abnormalities of the neurocranium, such as abscesses, CJD, etc. Similar diagnostic benefits could be anticipated from using DWI on orbital pathologies. High on the list of interesting pathologies are certainly periorbital dermoids/epidermois, fungal and pyogenic i...
متن کاملDiffusion-weighted imaging of the spine with readout-segmented (RS)-EPI
Introduction: The development of diffusion-weighted imaging (DWI) of the spine has been hindered by the large off-resonance effects problematic for single-shot EPI. Overcoming these restrictions would open up applications ranging from the diagnosis of spinal cord infarction, vertebral body fractures, lymphoma, trauma, and many other disorders. Navigated interleaved EPI has been shown to overcom...
متن کاملProspective Motion Correction with Stereoscopic Optical Tracking at 7T
INTRODUCTION Artifacts caused by motion during the image acquisition are a well known problem at 1.5T and 3T. In high field systems such as 7T the available signal to noise ratio leads to potentially higher resolution than in systems with lower field. Unfortunately higher resolution requires longer acquisition times without patient motion. Therefore an increased need for motion correction exist...
متن کاملWhole-Brain, Multi-Shot, Diffusion-Weighted Imaging in Humans at 7T with 1 mm Isotropic Resolution
Introduction: Diffusion-weighted, readout-segmented EPI (rs-EPI) with parallel imaging and 2D navigator correction [1] can provide substantially improved image quality compared to single-shot EPI (ss-EPI) with parallel imaging. The technique achieves a reduction in susceptibility artefacts and T2 image blurring by allowing a very short echo-spacing, which unlike ss-EPI does not increase with th...