Oxygen-iron interaction in liquid lead-bismuth eutectic alloy.

نویسندگان

  • A Aerts
  • S Gavrilov
  • G Manfredi
  • A Marino
  • K Rosseel
  • J Lim
چکیده

Iron released by steel corrosion was found to be a key impurity in reactions with dissolved oxygen in liquid lead-bismuth eutectic alloys. The iron-oxygen-magnetite equilibrium was characterized, allowing the quantification of phenomena that are important for long-term operation of lead-alloy based installations such as corrosion rate control and management of precipitates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Critical temperature of the lead–bismuth eutectic (LBE) alloy

Liquid metals such as Bi and Pb and Pb–Bi eutectic alloy are serious contenders for use as coolant in LMFBRs in lieu of sodium due to a number of attractive characteristics (high density, low moderation, low neutron absorption and activation, high boiling point and poor interaction with water and air, etc.). Analysis of hypothetical accidents is of relevance to predict the catastrophe involving...

متن کامل

Developing a Sensing System for the Measurement of Oxygen Concentration in Liquid Pb-Bi Eutectic

Although liquid lead-bismuth eutectic (LBE) is a good candidate for the coolant that can be employed in a subcritical transmutation blanket, it is known to be very corrosive to stainless steel, the material used in the containment structure. To mitigate this problem, trace levels of oxygen can be introduced into the system, causing the formation of a protective oxide layer at the interface betw...

متن کامل

Handbook on Lead-bismuth Eutectic Alloy and Lead Properties, Materials Compatibility, Thermal-hydraulics and Technologies

3.2 Enthalpies, entropies (solid and liquid state) – free energy and entropy of mixing The heats of formation of six solid Pb-Bi alloys have been measured at 400 K in a liquid lead solution calorimeter by P. Roy, et al. They found that these alloys obey Kopp’s law of additivity and the heats of formation are therefore temperature independent. The lead and bismuth used in these experiments were ...

متن کامل

Calibration of YSZ Sensors for the Measurement of Oxygen Concentration in Liquid Pb-Bi Eutectic

Although liquid lead-bismuth eutectic (LBE) is a good candidate for coolant in the subcritical transmutation blanket, it is known to be corrosive to stainless steel, the material of the carrying tubes and containers. Such longterm corrosion problem can be prevented by producing and maintaining a protective oxide layer on the exposed surface of stainless steel. For this purpose, it is required t...

متن کامل

Modeling Corrosion in Oxygen Controlled LBE Systems with Coupling of Chemical Kinetics and Hydrodynamics - Phase Three

The proposed work will combine chemical kinetics and hydrodynamics in target and test-loop lead-bismuth eutectic (LBE) systems to model system corrosion effects. This approach will result in a predicative tool that can be validated with corrosion test data, used to systematically design tests and interpret the results, and provide guidance for optimization in LBE system designs. The task includ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 18 29  شماره 

صفحات  -

تاریخ انتشار 2016