Quantitative Image Quality Comparison of Reduced- and Standard-Dose Dual-Energy Multiphase Chest, Abdomen, and Pelvis CT
نویسندگان
چکیده
We present a new image quality assessment method for determining whether reducing radiation dose impairs the image quality of computed tomography (CT) in qualitative and quantitative clinical analyses tasks. In this Institutional Review Board-exempt study, we conducted a review of 50 patients (male, 22; female, 28) who underwent reduced-dose CT scanning on the first follow-up after standard-dose multiphase CT scanning. Scans were for surveillance of von Hippel-Lindau disease (N = 26) and renal cell carcinoma (N = 10). We investigated density, morphometric, and structural differences between scans both at tissue (fat, bone) and organ levels (liver, heart, spleen, lung). To quantify structural variations caused by image quality differences, we propose using the following metrics: dice similarity coefficient, structural similarity index, Hausdorff distance, gradient magnitude similarity deviation, and weighted spectral distance. Pearson correlation coefficient and Welch 2-sample t test were used for quantitative comparisons of organ morphometry and to compare density distribution of tissue, respectively. For qualitative evaluation, 2-sided Kendall Tau test was used to assess agreement among readers. Both qualitative and quantitative evaluations were designed to examine significance of image differences for clinical tasks. Qualitative judgment served as an overall assessment, whereas detailed quantifications on structural consistency, intensity homogeneity, and texture similarity revealed more accurate and global difference estimations. Qualitative and quantitative results indicated no significant image quality degradation. Our study concludes that low(er)-dose CT scans can be routinely used because of no significant loss in quantitative image information compared with standard-dose CT scans.
منابع مشابه
Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملEstimation of Mean Patient Dose Indices in Chest and Abdomen/Pelvis CT Examinations in Rafsanjan Ali Ibn Abitalib Hospital in 2018: A Descriptive Study
Background and Objectives: The radiation protection of patients in CT examinations is important due to its wide application and high contribution in collective dose of public, and its radiation effects. The purpose of this study was to estimate the mean patient dose indices in chest and abdomen/pelvic examinations as the first step in patient radiation protection process. Materials and Methods...
متن کاملDiagnostic Reference Level of Computed Tomography Examinations and Need for Dose Optimization in Ondo State, Nigeria
Introduction: The present study was conducted to obtain State diagnostic reference levels (DRLs) of five routine computed tomography (CT) examinations from two CT centers in Ondo State and to identify factors responsible for dose variation and escalation in these CT centers. Material and Methods: Acquisition parameters and CT dose indices wer...
متن کاملSingle-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
BACKGROUND Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. METHODS This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 pati...
متن کاملOptimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2017