Analysis of Legionella pneumophila serogroup 1 isolates by pulsed-field gel electrophoresis.

نویسندگان

  • T J Marrie
  • S Tyler
  • G Bezanson
  • C Dendy
  • W Johnson
چکیده

At a hospital in Halifax, Nova Scotia, Canada, three strains of Legionella pneumophila were detectable based on plasmid content, while the isolates collected at another hospital in Halifax had no plasmids. Genomic DNA was digested with BssHII, SalI, and SpeI and subjected to pulsed-field gel electrophoresis (PFGE). We found no relationship between plasmid profile and PFGE pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unexpected similarity of pulsed-field gel electrophoresis patterns of unrelated clinical isolates of Legionella pneumophila, serogroup 1.

Phenotypic and genotypic methods identify subtypes of Legionella pneumophila, serogroup 1, and match patient and environmental isolates from suspected sources. The strength of this association is limited by the lack of information regarding the frequency and distribution of isolates belonging to various subtypes. In this study, 62 clinical isolates of L. pneumophila, serogroup 1, were subtyped ...

متن کامل

Comparative analysis of infrequent-restriction-site PCR and pulsed-field gel electrophoresis for epidemiological typing of Legionella pneumophila serogroup 1 strains.

Two methods were compared for the analysis of 48 unrelated and epidemiologically related Legionella pneumophila serogroup 1 isolates. These are the infrequent-restriction-site PCR (IRS-PCR) assay with adapters designed for XbaI and PstI restriction sites and the pulsed-field gel electrophoresis (PFGE) analysis determined after DNA restriction with SfiI. Both methods demonstrated a high level of...

متن کامل

Legionella pneumophila serogroup 1 strain Paris: endemic distribution throughout France.

An analysis of 691 French clinical Legionella isolates showed that the endemic L. pneumophila serogroup 1 strain Paris was responsible for 12.2% of all cases of legionellosis and had a specific pulsed-field gel electrophoresis pattern. We also demonstrated the presence of this endemic clone throughout Europe.

متن کامل

Legionella pneumonia due to exposure to 24-hour bath water contaminated by Legionella pneumophila serogroup-5.

A 79-year-old man was admitted to hospital from his nursing home for treatment of pneumonia, but died 7 days after admission. Legionella pneumonia was diagnosed after isolation of Legionella pneumophila serogroup-5 from sputum culture. The environment of the nursing home was investigated; only water specimens from the 24-hour bath were positive by culture for Legionella pneumophila serogroup-5....

متن کامل

Genomic Characterization of a Large Outbreak of Legionella pneumophila Serogroup 1 Strains in Quebec City, 2012

During the summer of 2012, a major Legionella pneumophila serogroup 1 outbreak occurred in Quebec City, Canada, which caused 182 declared cases of Legionnaire's disease and included 13 fatalities. Legionella pneumophila serogroup 1 isolates from 23 patients as well as from 32 cooling towers located in the vicinity of the outbreak were recovered for analysis. In addition, 6 isolates from the 199...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 1999