Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis

نویسندگان

  • Lonnie Froberg
  • Anders Troelsen
  • Michael Brix
چکیده

BACKGROUND AND PURPOSE Historically, the treatment of periprosthetic femoral fractures (PFFs) has been associated with a high frequency of complications and reoperations. The preferred treatment is internal fixation, a revision of the femoral stem, or a combination of both. An improved understanding of plate use during internal fixation, and the introduction of locking-plate osteosynthesis may lead to improved outcome. We evaluated the outcome of Vancouver type B1 and C PFFs treated by locking-plate osteosynthesis, by assessing rates of fracture union and reoperations and by analyzing failure cases. PATIENTS AND METHODS From 2002 through 2011, 58 consecutive patients (60 fractures) with low-energy PFF around or below a stable femoral stem, i.e. Vancouver type B1 and C fractures, underwent osteosynthesis with a locking plate. All patients had a total hip replacement (THR). They were followed up clinically and radiographically, with 6 weeks between visits, until fracture union or until death. Fracture union was evaluated 6 months postoperatively. RESULTS At a median follow-up time of 23 (0-121) months after PFF, 8 patients (8 fractures) had been reoperated due either to infection (n = 4), failure of fixation (n = 3), or loosening of the femoral stem (n = 1). All the patients who had been followed up for at least 6 months-and who did not undergo reoperation or die-went on to fracture union (n = 43). INTERPRETATION Locking-plate osteosynthesis of periprosthetic Vancouver type B1 and C fractures gives good results regarding fracture union. It appears that spanning of the prosthesis to avoid stress-rising areas is important for successful treatment. Infection is the major cause of failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment Results of a Periprosthetic Femoral Fracture Case Series: Treatment Method for Vancouver Type B2 Fractures Can Be Customized

BACKGROUND Currently, an algorithmic approach for deciding treatment options according to the Vancouver classification is widely used for treatment of periprosthetic femoral fractures after hip arthroplasty. However, this treatment algorithm based on the Vancouver classification lacks consideration of patient physiology and surgeon's experience (judgment), which are also important for deciding ...

متن کامل

Periprosthetic femur fractures, defined as femur frac- tures occurring around a pre-existing prosthetic hip or knee, are increasing in incidence on par with the number of arthroplasties

INTRODUCTION Periprosthetic femur fractures, defined as femur fractures occurring around a pre-existing prosthetic hip or knee, are increasing in incidence on par with the number of arthroplasties performed in our increasingly aging population. Periprosthetic hip fractures most commonly occur around or just distal to a hip stem prosthesis (Vancouver Type B, 88%) [1], and periprosthetic distal f...

متن کامل

Reversed Contralateral LISS Plate for Vancouver B1 Periprosthetic Femoral Shaft Fractures.

The authors reviewed all patients treated for periprosthetic femur fractures between March 1, 2007, and January 31, 2010 at the senior author's institution. Demographic features, mechanism of injury, radiographs, and computed tomography scans were reviewed to determine the type and stability of the femoral implant at the time of injury. All Vancouver B1 fractures were treated with a novel techn...

متن کامل

Treatment of Vancouver B1 fractures—contemporary principles for the use of locking plates

A number of factors complicate the treatment of periprosthetic fractures of the proximal femur. These include bone quality, fixation of the stem, relation of the fracture to the stem, healing potential of the bone and the patient's future risk of another fall. Vancouver type B1 fractures are commonly fixed with locking plates, but even though results have improved, complication rate is still ra...

متن کامل

The use of an interference fit retrograde nail as an adjunct to plate fixation of a complex Vancouver B1 periprosthetic femoral fracture.

As the number of hip arthroplasties performed continues to grow, increasingly complex periprosthetic fractures are encountered. In particular, fractures occurring near the tip of a well-fixed stem, classified as Vancouver B1, have been associated with high rates of failure. Numerous treatment strategies have been recommended including traditional plating, locked plating, cortical allografts as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 83  شماره 

صفحات  -

تاریخ انتشار 2012