Using the Portapres® for the measurement of toe arterial blood pressure during movement: is it valid and reliable?

نویسندگان

  • Joshua A Goreham
  • Derek S Kimmerly
  • Michel Ladouceur
چکیده

The aim of the study was to assess the validity and reliability of using the Portapres® to measure toe blood pressure during rest and exercise. Construct validity, concurrent validity, and interday reliability were assessed by measuring toe (Portapres®)) and brachial blood pressure in 16 nondisabled participants on consecutive days. Construct validity was assessed by pedaling on a cycle ergometer (6 revolutions per minute) and comparing the measured toe blood pressure to an estimated value based on orthostatic factors. Concurrent validity was assessed by comparing toe and brachial blood pressure during supine rest and following 10 min of cycling exercise. Interday reliability was assessed by recording toe and brachial blood pressure during supine rest on a second day. Construct validity analysis shows that the toe blood pressure signal was moderately correlated with the changes in heart-toe distance and that changes in toe blood pressure during slow cycling were similar to the estimated value. Resting toe and brachial mean arterial blood pressure showed concurrent validity with only a fixed bias explained by the change in orthostatic pressure and the toe-brachial index. Furthermore, cycling exercise was associated with an increase in brachial and a decrease in toe mean blood pressure. The interday reliability analysis showed no proportional or fixed bias for mean arterial blood pressure. Our study showed the feasibility of using the Portapres® to measure toe blood pressure during movement and can be used to study the effect of movement-related forces during cycling on toe blood pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

تأثیر ساکشن لوله داخل نای بر وضعیت همودینامیک واکسیژناسیون خون شریانی

  Background and Aim: Intratracheal suctioning is a standard method of nursing care for intubated patients with the aim of cleaning airway for good oxygenation. The aim of this study was to evaluate the effects of intratracheal suctioning on blood pressure, heart rate, and arterial oxygen saturation.   Materials and Methods: This was a semi-experimental research in which the patients admitted t...

متن کامل

Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.

We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record signals on tape, to alternate measurements between fingers automatically each 30 minutes, and to corr...