Cerebral complications following measurements of regional cerebral blood flow (rCBF) with the intra-arterial 133Xenon injection method.

نویسندگان

  • D H Ingvar
  • N A Lassen
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral Complications Following Measurements

Cerebral Complications Following Measurements of Regional Cerebral Blood Flow (rCBF) With the Intra-arterial Injection Method • The rate of complications was studied following measurements of regional cerebral blood flow (rCBF) with the intra-arterial Xenon technique. The investigation was based upon reports of rCBF measurements in close to 4,000 patients, carried out at 18 European and America...

متن کامل

Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio

 Objective(s): Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H215O positron emission tomography. Clarification of differences in r...

متن کامل

Correlation between regional cerebral blood flow and brain atrophy in dementia. Combined study with 133Xenon inhalation and computerised tomography.

Measurement of the regional cerebral blood flow (rCBF) by the 133Xenon inhalation method and computerised tomography were performed in 25 patients with presenile and senile dementia. Reduction of rCBF and various degrees of ventricular enlargement and cortical sulcal widening were demonstrated in the majority of demented subjects. However, there was no correlation between rCBF values and the se...

متن کامل

Evaluation of human hemispheric blood flow based on non invasive carotid blood flow measurements using the range-gated Doppler technique.

Common carotid blood flow (CCBF) was measured in 11 anesthetised patients without extracranial arterial disease (nine acute subarachnoid haemorrhages and two cases of head injury). The range-gated Doppler flowmeter with an adjustable range-gated time system and a double transducer probe was used to determine diameter, blood velocity, and blood flow of the common carotid artery. Values were, res...

متن کامل

Quantitative Assessment of Cerebral Blood Flow Measure- ment Using the Microsphere Model with N-isopropyl-p-[123I] iodoamphetamine SPECT: Simulation Analysis for the Influence of Washout from Brain Tissue

The microsphere model and the continuous withdrawal of arterial blood have been commonly used in clinical studies when measuring regional cerebral blood flow (rCBF) by N-isopropyl-p[123I]iodoamphetamine (IMP) SPECT. The method is considered to underestimate rCBF because of the washout of the tracer from brain tissue with increasing time after injection; however, the extent of this underestimati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 1973