Evaluation of a rapid immunochromatographic test for detection of antibodies to human immunodeficiency virus.

نویسندگان

  • H Arai
  • B Petchclai
  • K Khupulsup
  • T Kurimura
  • K Takeda
چکیده

A new immunochromatographic rapid test, Determine HIV-1/2, for the detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 in human whole blood, serum, and plasma was evaluated. Determine HIV-1/2 is a sandwich immunoassay and uses a nitrocellulose strip with a capture site for the patient's results and a procedural control site to confirm the validity of the assay. The results can be read visually, and a positive result is indicated by the formation of a red line within 15 min after sample application. The test showed 100% sensitivity for HIV-1 with 102 whole-blood, 152 serum, and 144 plasma samples obtained from Ramathibodi Hospital, Bangkok, Thailand. The sensitivity of the test for HIV-2 was 100% with 100 serum or plasma samples obtained from Ivory Coast. The sensitivity of the test with 4 anti-HIV-1 seroconversion panels from Boston Biomedica Inc. was equivalent to or better than those of another agglutination assay with serum or plasma and the enzyme immunoassay licensed by the U.S. Food and Drug Administration. The specificity was 100% with 367 sets of whole-blood, serum, and plasma samples from Ramathibodi Hospital. This method had an analytical sensitivity for the detection of HIV-1 equivalent to or better than that of another agglutination assay with serum or plasma. This test had an analytical sensitivity for the detection of HIV-1 better than that of another immunochromatographic test with whole blood. This evaluation demonstrated the excellent performance of this immunochromatographic test with EDTA-anticoagulated whole-blood, serum, and plasma samples. We conclude that this test is suitable for use in emerging countries and is an excellent alternative to HIV antibody testing at remote sites, as well as in traditional laboratories.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a rapid immunochromatographic screening test for detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2: experience at a tertiary care hospital in South India.

The performance characteristics of a rapid immunochromatographic-screening test, SD Bioline HIV-1/2 3.0 (Standard Diagnostics Inc., Kyonggi-do, South Korea) on 23,754 sera and 30 plasma samples are reported. The sensitivity and specificity for the assay on serum samples are 100% and 99.4%, respectively. The assay detected antibodies in individuals infected with human immunodeficiency virus type...

متن کامل

Assessment of a rapid immunochromatographic assay for the detection of avian influenza viruses

Rapid spreading of the low pathogenic avian influenza virus (AIV) caused by the H9N2 subtype and the highly pathogenic AIV caused by H5N1 have caused serious economic losses in the poultry industries of Asia. Therefore, the early detection of AIVs is crucial for the control of the disease. In the present study, the applicability of a rapid immunochromatographic (RIC) assay, which specifically d...

متن کامل

APPLICATION OF DOT IMMUNOASSAY (DIA) FOR DETECTION AND TITRATION OF MEASLES VIRUS ANTIBODIES

Measles is one of the most contagious human diseases. Although mass vaccination programs have reduced the incidence of this disease, measles is still an important cause of morbidity and mortality among children in developing countries. Therefore the use of sensitive techniques to evaluate vaccine efficacy and level of immunity among members of susceptible communities is crucial. Serum neut...

متن کامل

Quantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies

Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...

متن کامل

Comparison of a new immunochromatographic test to enzyme-linked immunosorbent assay for rapid detection of immunoglobulin m antibodies to hepatitis e virus in human sera.

An immunochromatographic test for rapid detection of IgM antibodies in patients with acute hepatitis E infection was developed utilizing the well-characterized recombinant protein EP2.1 and monoclonal antibody 4B2. The new rapid test based on a novel reverse-flow technology was able to generate a positive result within 2 to 3 min. Our study showed that this test was able to detect anti-HEV IgM ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 1999