Stentless vs. stented bioprosthesis for aortic valve replacement: A case matched comparison of long-term follow-up and subgroup analysis of patients with native valve endocarditis

نویسندگان

  • Andreas Schaefer
  • Jannis Dickow
  • Gerhard Schoen
  • Sumi Westhofen
  • Lisa Kloss
  • Tarik Al-Saydali
  • Hermann Reichenspurner
  • Sebastian A Philipp
  • Christian Detter
چکیده

BACKGROUND Current retrospective evidence suggests similar clinical and superior hemodynamic outcomes of the Sorin Freedom Solo stentless aortic valve (SFS) (LivaNova PLC, London, UK) compared to the Carpentier Edwards Perimount stented aortic valve (CEP) (Edwards Lifesciences Inc., Irvine, California, USA). To date, no reports exist describing case-matched long-term outcomes and analysis for treatment of native valve endocarditis (NVE). METHODS From 2004 through 2014, 77 consecutive patients (study group, 59.7% male, 68.9 ± 12.5 years, logEuroSCORE II 7.6 ± 12.3%) received surgical aortic valve replacement (SAVR) with the SFS. A control group of patients after SAVR with the CEP was retrieved from our database and matched to the study group regarding 15 parameters including preoperative endocarditis. Acute perioperative outcomes and follow-up data (mean follow-up time 48.7±29.8 months, 95% complete) were retrospectively analyzed. RESULTS No differences in early mortality occurred during 30-day follow up (3/77; 3.9% vs. 4/77; 5.2%; p = 0.699). Echocardiographic findings revealed lower postprocedural transvalvular pressure gradients (max. 17.0 ± 8.2 vs. 24.5 ± 9.2 mmHg, p< 0.001/ mean pressure of 8.4 ± 4.1 vs. 13.1 ± 5.9 mmHg, p< 0.001) in the SFS group. Structural valve degeneration (SVD) (5.2% vs. 0%; p = 0.04) and valve explantation due to SVD or prosthetic valve endocarditis (PVE) (9.1% vs. 1.3%; p = 0.04) was more frequent in the SFS group. All-cause mortality during follow-up was 20.8% vs. 14.3% (p = 0.397). When patients were divided into subgroups of NVE and respective utilized bioprosthesis, the SFS presented impaired outcomes regarding mortality in NVE cases (p = 0.031). CONCLUSIONS The hemodynamic superiority of the SFS was confirmed in this comparison. However, clinical outcomes in terms of SVD and PVE rates, as well as survival after NVE, were inferior in this study. Therefore, we are reluctant to recommend utilization of the SFS for treatment of NVE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis

BACKGROUND We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. METHODS One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical pr...

متن کامل

Long-term clinical and echocardiographic follow-up of the freestyle stentless aortic bioprosthesis: the Tel Aviv Medical Center experience.

BACKGROUND Stentless aortic bioprostheses were designed to provide improved hemodynamic performance and potentially better survival. OBJECTIVES To report the outcomes of patients after aortic valve replacement with the Freestyle stentless bioprosthesis at the Tel Aviv Medical Center followed for < or = 15 years. METHODS AND RESULTS Between 1997 and 2011, 268 patients underwent primary aorti...

متن کامل

Freestyle stentless bioprosthesis for aortic valve therapy: 17-year clinical results.

BACKGROUND Aortic valve replacement with stentless bioprostheses has been shown to produce lower aortic gradients than stented bioprostheses, thus facilitating left ventricular mass regression and preventing heart failure. We sought to determine the long-term results of stentless biological aortic valve replacement over a 17-year follow-up. METHODS Between 1996 and 2012, 2551 patients underwe...

متن کامل

Aortic valve replacement with stentless and stented porcine valves: a case-match study.

OBJECTIVES To assess the potential benefits of the hemodynamic superiority of stentless valves, we conducted a case-match study among patients who underwent aortic valve replacement with two types of porcine bioprostheses: the Toronto SPV and the stented Hancock II bioprosthesis. METHODS Preoperative clinical variables predictive of death after aortic valve replacement were determined by a st...

متن کامل

Stentless vs. stented aortic valve bioprostheses: a prospective randomized controlled trial.

AIMS We sought to assess the haemodynamic profile of the Freedom stentless aortic valve compared with a stented bioprosthesis in a randomized controlled trial using echocardiography. METHODS AND RESULTS Sixty patients (mean age 73 years) undergoing bioprosthetic aortic valve replacement (AVR) were randomized to either Sorin Freedom stentless (n=31) or Sorin More stented (n=29) valves. The pri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018