99mTc-3P4-RGD2 Scintimammography in the Assessment of Breast Lesions: Comparative Study with 99mTc-MIBI

نویسندگان

  • Qingjie Ma
  • Bin Chen
  • Shi Gao
  • Tiefeng Ji
  • Qiang Wen
  • Yan Song
  • Lei Zhu
  • Zheli Xu
  • Lin Liu
  • Jason Mulvenna
چکیده

PURPOSE To compare the potential application of (99m)Tc-3P-Arg-Gly-Asp ((99m)Tc-3P4-RGD2) scintimammography (SMM) and (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SMM for the differentiation of malignant from benign breast lesions. METHOD Thirty-six patients with breast masses on physical examination and/or suspicious mammography results that required fine needle aspiration cytology biopsy (FNAB) were included in the study. (99m)Tc-3P4-RGD2 and (99m)Tc-MIBI SMM were performed with single photon emission computed tomography (SPECT) at 60 min and 20 min respectively after intravenous injection of 738 ± 86 MBq radiotracers on a separate day. Images were evaluated by the tumor to non-tumor localization ratios (T/NT). Receiver operating characteristic (ROC) curve analysis was performed on each radiotracer to calculate the cut-off values of quantitative indices and to compare the diagnostic performance for the ability to differentiate malignant from benign diseases. RESULTS The mean T/NT ratio of (99m)Tc-3P4-RGD2 in malignant lesions was significantly higher than that in benign lesions (3.54 ± 1.51 vs. 1.83 ± 0.98, p<0.001). The sensitivity, specificity, and accuracy of (99m)Tc-3P4-RGD2 SMM were 89.3%, 90.9% and 89.7%, respectively, with a T/NT cut-off value of 2.40. The mean T/NT ratio of (99m)Tc-MIBI in malignant lesions was also significantly higher than that in benign lesions (2.86 ± 0.99 vs. 1.51 ± 0.61, p<0.001). The sensitivity, specificity and accuracy of (99m)Tc-MIBI SMM were 87.5%, 72.7% and 82.1%, respectively, with a T/NT cut-off value of 1.45. According to the ROC analysis, the area under the curve for (99m)Tc-3P4-RGD2 SMM (area = 0.851) was higher than that for (99m)Tc-MIBI SMM (area = 0.781), but the statistical difference was not significant. CONCLUSION (99m)Tc-3P4-RGD2 SMM does not provide any significant advantage over the established (99m)Tc-MIBI SMM for the detection of primary breast cancer. The T/NT ratio of (99m)Tc-3P4-RGD2 SMM was significantly higher than that of (99m)Tc-MIBI SMM. Both tracers could offer an alternative method for elucidating non-diagnostic mammograms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Exploratory Study on 99mTc-RGD-BBN Peptide Scintimammography in the Assessment of Breast Malignant Lesions Compared to 99mTc-3P4-RGD2

PURPOSE This study aimed to explore the diagnostic performance of single photon emission computed tomography / computerized tomography (SPECT/CT) using a new radiotracer 99mTc-RGD-BBN for breast malignant tumor compared with 99mTc-3P4-RGD2. METHODS 6 female patients with breast malignant tumors diagnosed by fine needle aspiration cytology biopsy (FNAB) who were scheduled to undergo surgery we...

متن کامل

بررسی ارزش تشخیصی اسکن 99mTc-MIBI (Scintimammography) در بدخیمی های پستان

The breast cancer is common in females.Early detection with safe ,&nbsp;convenient , noninvasive and accessible diagnostic tools are important. X- ray mammography is still the first choice imaging for breast cancer, but has&nbsp;low specificity and limited value in dense breast and surgically scarred&nbsp;breasts. In recent years , MIBI scintimammography has been used for this&nbsp;purpose. The...

متن کامل

Diagnostic value of 99mTc MIBI scintimammography in patients with breast lesions.

This study has aimed to determine the diagnostic value of the scintimammography with 99mTc-MIBI in the detection of primary breast cancer and to verify its clinical usefulness. Sixty-three female patients (age range 27-83) with breast lesions detected by physical examination, ultrasonography, and/or mammography were prospectively included in this study. An anterior and prone lateral planar 99mT...

متن کامل

Breast parenchymal activity on scintimammography: comparison between bone-seeking agents and 99mTc-sestamibi.

The aim of this study was to evaluate breast parenchymal activity on scintimammography with bone-seeking agents and 99mTc-MIBI. Scintimammography was performed with bone-seeking agents in 61 patients and with 99mTc-MIBI in 33 patients. Activity in the breast parenchyma contralateral to the suspected lesion was visually assessed by two independent observers. Increased breast parenchymal activity...

متن کامل

Comparison of 99mTc-MDP and 99mTc-MIBI whole body scans for diagnosis of widespread skeletal metastases [Persian]

Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient’s life, both quantitatively and qualitatively, and prevent exacerbation of the disease and disabling complications. In this study, 22 patients with est...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014