Computer-automated tinnitus assessment using patient control of stimulus parameters.
نویسندگان
چکیده
A need exists for a standardized tinnitus evaluation tool to measure "acoustic" parameters of tinnitus. An automated tinnitus evaluation system has been developed in this laboratory, consisting of a patient-controlled touch-screen computer monitor, main computer, and Programmable Auditory Laboratory 3000 (PAL 3000) (a custom-built signal conditioning module). The system obtains and records data from tinnitus patients, including hearing thresholds and the pitch and loudness of their tinnitus. New features have been incorporated into the system to make it more user-friendly and practical for clinical application. Using the system, we evaluated 40 individuals with tinnitus to assess within- and between-session reliability of responses. Response reliability has been documented with previous versions of the system. Incorporating the new features has reduced testing time to an average of less than 19 minutes and has resulted in comparable loudness-match reliability and improved pitch-match reliability compared with the previous results. These data support the technique as suitable for clinical application, indicating the need to develop instrumentation for this purpose.
منابع مشابه
Impact of visual disorders on vestibular and balance rehabilitation therapy outcomes in soldiers with blast injury.
INTRODUCTION One of the standard measurements in the evaluation process is quantifying the tinnitus frequency. With advancements in the treatments of tinnitus, the need for a simple patient-directed automated tinnitus assessment is urging. OBJECTIVES To investigate the accuracy of a web-based protocol for tinnitus frequency matching in comparison to audiometry. MATERIALS AND METHODS Twenty ...
متن کاملTinnitus suppression by electric stimulation of the auditory nerve
Electric stimulation of the auditory nerve via a cochlear implant (CI) has been observed to suppress tinnitus, but parameters of an effective electric stimulus remain unexplored. Here we used CI research processors to systematically vary pulse rate, electrode place, and current amplitude of electric stimuli, and measure their effects on tinnitus loudness and stimulus loudness as a function of s...
متن کاملComputer-automated tinnitus assessment: noise-band matching, maskability, and residual inhibition.
BACKGROUND Psychoacoustic measures of tinnitus typically include loudness and pitch match, minimum masking level (MML), and residual inhibition (RI). We previously developed and documented a computer-automated tinnitus evaluation system (TES) capable of subject-guided loudness and pitch matching. The TES was further developed to conduct computer-aided, subject-guided testing for noise-band matc...
متن کاملComparison of manual and computer-automated procedures for tinnitus pitch-matching.
Clinical assessment of tinnitus usually includes pitch-matching between the tinnitus and a pure tone. Although such testing is performed routinely, response reliability has not been demonstrated yet. The present study continues a series of studies designed to develop automated methodology for quantifying tinnitus perceptual characteristics. Three methods for tinnitus pitch-matching were perform...
متن کاملThe relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus
Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and withou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of rehabilitation research and development
دوره 41 6A شماره
صفحات -
تاریخ انتشار 2004