Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
نویسندگان
چکیده
BACKGROUND There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. OBJECTIVES To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. METHODS A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Gold-standard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on low-resolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. RESULTS Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39-0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. CONCLUSIONS Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes.
منابع مشابه
Feasibility of Brain Atrophy Measurement in Clinical Routine without Prior Standardization of the MRI Protocol: Results from MS-MRIUS, a Longitudinal Observational, Multicenter Real-World Outcome Study in Patients with Relapsing-Remitting MS.
BACKGROUND AND PURPOSE Feasibility of brain atrophy measurement in patients with MS in clinical routine, without prior standardization of the MRI protocol, is unknown. Our aim was to investigate the feasibility of brain atrophy measurement in patients with MS in clinical routine. MATERIALS AND METHODS Multiple Sclerosis and Clinical Outcome and MR Imaging in the United States (MS-MRIUS) is a ...
متن کاملQuantitative diVusion weighted magnetic resonance imaging, cerebral atrophy, and disability in multiple sclerosis
Objectives—To investigate the relations between quantitative diVusion coeYcient MRI histograms, clinical variables, and cerebral atrophy. Methods—Twenty two patients with clinically definite multiple sclerosis and 11 healthy volunteers were studied. Histograms of apparent diVusion coeYcient (ADC) from a volume of interest that included multiple slices encompassing the lateral ventricles were pr...
متن کاملAre Periventricular Lesions Specific for Multiple Sclerosis?
BACKGROUND The presence of periventricular lesions (PVL) on MRI scans is part of the revised McDonald multiple sclerosis (MS) diagnostic criteria. However, PVL can be found in other neurological diseases including stroke and migraine. Migraine is highly prevalent in patients with MS. OBJECTIVE To determine if PVL are specific for patients with MS compared to stroke and migraine. METHODS We ...
متن کاملAn Observational Study to Assess Brain MRI Change and Disease Progression in Multiple Sclerosis Clinical Practice—The MS‐MRIUS Study
BACKGROUND & PURPOSE To describe methodology, interim baseline, and longitudinal magnetic resonance imaging (MRI) acquisition parameter characteristics of the multiple sclerosis clinical outcome and MRI in the United States (MS-MRIUS). MATERIAL & METHODS The MS-MRIUS is an ongoing longitudinal and retrospective study of MS patients on fingolimod. Clinical and brain MRI image scan data were co...
متن کاملCorrelation of MRI findings and cognitive function in multiple sclerosis patients using montreal cognitive assessment test
Background: Magnetic resonance imaging (MRI) has improved the diagnosis and management of patients with multiple sclerosis (MS). Montreal Cognitive Assessment (MoCA) is a brief, sensitive test that has been recommended by National Institute of Neurological Diseases and Stroke and Canadian Stroke Network (NINDS-CSN) as a reliable tool to detect mild cognitive impairments. This study aimed to eva...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2017