Improved quantification of small objects in near-infrared diffuse optical tomography.

نویسندگان

  • Subhadra Srinivasan
  • Brian W Pogue
  • Hamid Dehghani
  • Shudong Jiang
  • Xiaomei Song
  • Keith D Paulsen
چکیده

Diffuse optical tomography allows quantification of hemoglobin, oxygen saturation, and water in tissue, and the fidelity in this quantification is dependent on the accuracy of optical properties determined during image reconstruction. In this study, a three-step algorithm is proposed and validated that uses the standard Newton minimization with Levenberg-Marquardt regularization as the first step. The second step is a modification to the existing algorithm using a two-parameter regularization to allow lower damping in a region of interest as compared to background. This second stage allows the recovery of the actual size of an inclusion. A region-based reconstruction is the final third step, which uses the estimated size and position information from step 2 to yield quantitatively accurate average values for the optical parameters. The algorithm is tested on simulated and experimental data and is found to be insensitive to object contrast and position. The percentage error between the true and the average recovered value for the absorption coefficient in test images is reduced from 47 to 27% for a 10-mm inclusion, from 38 to 13% for a 15-mm anomaly, and from 28 to 5.5% for a 20-mm heterogeneity. Simulated data with absorbing and scattering heterogeneities of 15 mm diam located in different positions show recovery with less than 15% error in absorption and 6% error in reduced scattering coefficients. The algorithm is successfully applied to clinical data from a subject with a breast abnormality to yield quantitatively increased absorption coefficients, which enhances the contrast to 3.8 compared to 1.23 previously.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Generalized Least-squares minimization method for near infrared diffuse optical tomography

Diffuse optical tomography (DOT) has the potential to become a non-invasive and non-ionizing diagnostic imaging technique for breast cancer imaging. DOT uses near-infrared (NIR) light to illuminate the breast, generally through the use of fiber optic bundles, and the diffusely transmitted light is collected from the tissue surface. To get functional images of the breast, one needs to use advanc...

متن کامل

Near-Infrared Diffuse Optical Tomography

Diffuse optical tomography (DOT) is emerging as a viable new biomedical imaging modality. Using near-infrared (NIR) light, this technique probes absorption as well as scattering properties of biological tissues. First commercial instruments are now available that allow users to obtain cross-sectional and volumetric views of various body parts. Currently, the main applications are brain, breast,...

متن کامل

Time reversal optical tomography: locating targets in a highly scattering turbid medium

A time reversal optical tomography (TROT) method for near-infrared (NIR) diffuse optical imaging of targets embedded in a highly scattering turbid medium is presented. TROT combines the basic symmetry of time reversal invariance and subspace-based signal processing for retrieval of target location. The efficacy of TROT is tested using simulated data and data obtained from NIR imaging experiment...

متن کامل

Early-photon fluorescence tomography: spatial resolution improvements and noise stability considerations.

In vivo tissue imaging using near-infrared light suffers from low spatial resolution and poor contrast recovery because of highly scattered photon transport. For diffuse optical tomography (DOT) and fluorescence molecular tomography (FMT), the resolution is limited to about 5-10% of the diameter of the tissue being imaged, which puts it in the range of performance seen in nuclear medicine. This...

متن کامل

On the suitability of Near-Infrared Systems for Next Generation Brain Computer Interfaces

Introduction Since Near-Infrared Spectroscopy (NIRS) was first reported in 1977 by Jobsis[1] as a new “window” into the body, it has found many uses within the biomedical field. Single channel near-infrared systems are most commonly used in clinical surroundings for transcranial cerebral oximetry in neonatal care, hematoma detection, and stroke patient monitoring. In addition to its clinical us...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 9 6  شماره 

صفحات  -

تاریخ انتشار 2004