Project : VDSL Title : Evaluation of network topologies for PBO studies

نویسنده

  • Sigurd Schelstraete
چکیده

We study upstream capacity in the network topologies that have been proposed for PBO studies and compare with the upstream capacity that can be obtained when assuming worst-case FEXT. We find that the worst-case FEXT gives a rather tight lower bound for the capacities that are obtained in each of the proposed topologies. Status: For information

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of the Cable Bundle Unique Power Back-Off Algorithm

The latest digital subscriber line (DSL) technology, VDSL2, used for broadband access over twisted-pairs, promises up to 100 Mbit/s for both transmission directions on short loops. Since these systems are designed to operate in a far-end crosstalk (FEXT) limited environment, there is a severe performance degradation when deployed in distributed network scenarios. With power back-off (PBO) the n...

متن کامل

Optimal Coordination of Distance and Directional Overcurrent Relays Considering Different Network Topologies

Most studies in relay coordination have focused solely on coordination of overcurrent relays while distance relays are used as the main protection of transmission lines. Since, simultaneous coordination of these two types of relays can provide a better protection, in this paper, a new approach is proposed for simultaneous coordination of distance and directional overcurrent relays (D&DOCRs). Al...

متن کامل

Spectral Compatibility of ADSL and VDSL, Part 2: The Impact of ADSL on VDSL Performance

This contribution examines the effect of ADSL on VDSL when both reside in a single binder group. The potential loss in VDSL bit rate due to the presence of ADSL is qualified using channel capacity arguments. Of particular interest is the impact of the ADSL PSD beyond 1.104 MHz on VDSL performance, as high-level ADSL energy in this region can substantially impair achievable VDSL bit rates. The c...

متن کامل

Electrochemical Evaluation of PbO Nanoparticles as Anode for Lithium Ion Batteries (Technical Note)

PbO nanoparticles were synthesized using hydrothermal process. Scanning electron microscopy (SEM) was used in order to investigate of PbO powders. X-ray diffraction (XRD) pattern confirmed β-PbO formation during this process. The crystallite size of the powders was calculated using Scherrer formula about 74.6 nm. Electrochemical evaluation of the PbO nanoparticles as anode for Li-ion batteries ...

متن کامل

The Impact of Upstream Power Back-off on VDSL Frequency Planning

This contribution points out the need to consider power back-off in the upstream direction when VDSL frequency plan alternatives are evaluated. It is shown that upstream power back-off, which is necessary in distributed topologies, can affect the bit rates achievable with any chosen frequency plan. Also shown is that certain power backoff methods result in achievable bit rates that are very clo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000