Influence of exercise on the structure of the anterior chamber of the eye
نویسندگان
چکیده
PURPOSE To measure changes in anterior chamber structure before and after exercise in healthy individuals using anterior segment optical coherence tomography (ASOCT). METHODS Thirty-two healthy young individuals performed jogging for 20 min. Eye blinking rate was recorded during rest and exercise. The anterior chamber angle (ACA), angle opening distance at 500 μm from the scleral spur (AOD500), trabecular-iris space area at 500 μm from the scleral spur (TISA500), iris concavity (IC), iris concavity ratio (CR), iris thickness at 750 μm from the scleral spur (IT750), anterior chamber depth (ACD), anterior chamber width (ACW), pupil diameter (PD), intraocular pressure (IOP), blood pressure (BP) and heart rate (HR) were recorded before and after exercise. Anterior chamber angle (ACA), AOD500, TISA500, IC, IT750, ACD, ACW and PD were measured with ASOCT. RESULTS Compared with rest, the blinking rate during exercise did not change significantly (13.04 ± 5.80 versus 13.52 ± 5.87 blinks/min, p = 0.645). The average IOP (15.4 ± 2.4 versus 12.4 ± 2.1 mmHg), ACA (35.96 ± 11.35 versus 40.25 ± 12.64 degrees), AOD500 (0.800 ± 0.348 versus 0.942 ± 0.387 mm), TISA500 (0.308 ± 0.155 versus 0.374 ± 0.193 mm2 ), IC (-0.078 ± 0.148 versus -0.153 ± 0.159 mm) and CR (-0.027 ± 0.050 versus -0.054 ± 0.056) changed significantly (all p < 0.001), while the average IT750 (0.463 ± 0.084 versus 0.465 ± 0.086 mm; p = 0.492), ACD (3.171 ± 0.229 versus 3.175 ± 0.238 mm; p = 0.543) and ACW (11.768 ± 0.377 versus 11.755 ± 0.378 mm; p = 0.122) showed no significant change after exercise. CONCLUSION The blinking rate did not change significantly during exercise, while ACA, AOD500 and TISA500 increased after exercise. Exercise also induced or increased IC. These changes in anterior chamber structure were only associated with exercise, but not with the postexercise change in PD or IOP.
منابع مشابه
Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues
Introduction: The present study aimed to present a numerical analysis of the penetration depth, specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...
متن کاملSecondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog
The present study introduces a rare case with secondary glaucoma due to anterior chamber lipoma and uveitis in a Pekingese dog in Iran. A four-year-old castrated male Pekingese dog was referred to the private clinic with impaired vision of the left eye, pain, rubbing the left eye onto carpet, presence of a milkycoloured mass into the anterior chamber, and loss of appetite. The clinical examinat...
متن کاملOcular Ultrasonographic Features in Iranian Native Donkey
Objective- The aim of this study was to evaluate ultrasonographic appearance of the normal eye and obtaining reference values of ocular structures in Iranian native donkey. Design- Experimental study. Animals- Five Iranian native donkeys. Procedures- After preparation of the animals, ocular structures were ima...
متن کاملUnilateral Anterior Non-Granulomatous Uveitis as COVID-19 Complication
Background: Since prevalence of the Severe Acute Respiratory Syndrome 2 (SARS-CoV-2), millions of infected people presented with various manifestations. Some studies report ocular complications, such as conjunctivitis and sub-conjunctival haemorrhage, as an initial manifestation of Corona Virus Disease 2019 (COVID-19). This article aims to report unilateral acute anterior non-granulomatous uvei...
متن کاملMagnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 96 شماره
صفحات -
تاریخ انتشار 2018