Naturally occurring interference in Luminex assays for HLA-specific antibodies: characteristics and resolution.

نویسندگان

  • Andrea A Zachary
  • Donna P Lucas
  • Barbara Detrick
  • Mary S Leffell
چکیده

Substances occurring naturally in the sera of patients can interfere with Luminex antibody assays, causing increased background and changes in antibody specificity. We present data on the effectiveness of hypotonic dialysis (HD) or dithiothreitol (DTT) treatment in eliminating this interference. HD significantly increased reaction strength of positive control beads and reduced reaction strength of negative control beads. HD also improved specificity identification, determination of donor-specific antibody (DSA) strength, and crossmatch predictability compared with values in untreated serum. DTT also increased the reaction strength of positive control beads, but in most cases, further increased reactivity of negative control beads. DTT improved crossmatch predictability but to a lesser extent than did HD and may differ with specificities defined in other assays. Because interference is frequently observed in sera from highly sensitized patients, it is important to recognize and eliminate interference in Luminex antibody assays for accurate and meaningful test interpretation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human leukocyte antigen epitope analysis to assess complement- and non-complement-binding donor-specific antibody repertoire in a pediatric heart transplant recipient.

This case report summarizes the spectrum of anti-human leukocyte antigen (HLA) antibody reactivity determined by single-allele Luminex immunoglobulin G and C1q binding assays before transplant, during an episode of antibody-mediated rejection (AMR), and following treatment in a sensitized pediatric heart transplant (Tx) recipient. We were able to discriminate between complement- and non-complem...

متن کامل

Technical Limitations of the C1q Single-Antigen Bead Assay to Detect Complement Binding HLA-Specific Antibodies

BACKGROUND Solid-phase assays to distinguish complement binding from noncomplement binding HLA-specific antibodies have been introduced, but technical limitations may compromise their interpretation. We have examined the extent to which C1q-binding to HLA-class I single-antigen beads (SAB) is influenced by denatured HLA on SAB, antibody titre, and complement interference that causes a misleadin...

متن کامل

C4d fixing, luminex binding antibodies - a new tool for prediction of graft failure after heart transplantation.

The standard method to detect pretransplant antibodies has been the complement dependent cytotoxicity (CDC) test of donor leukocytes. Solid phase assays to detect HLA antibodies in pretransplant serum reveal a greater number of sensitized patients, but their clinical impact is less certain. Here we have developed a method of detecting C4d fixing HLA antibodies on Luminex beads. Pretransplant se...

متن کامل

The complexity of human leukocyte antigen (HLA)-DQ antibodies and its effect on virtual crossmatching.

BACKGROUND We previously reported that in patients possessing human leukocyte antigen (HLA)-DQ-directed antibodies, the target molecule may include the patient's own DQβ chain if it is paired with non-self-DQα chain, thus forming a different DQ target. Herein, we sought to assess the breadth of this phenomenon. METHODS Serum samples from 104 patients awaiting kidney transplantation, known to ...

متن کامل

Methodologies for anti-HLA antibody screening in patients awaiting kidney transplant: a comparative study.

OBJECTIVES The relevance of anti-HLA antibodies in patients awaiting kidney transplants is well recognized. During the past 40 years, kidney transplant candidates have been tested for these antibodies, and the choice of the detection assay has become essential. Recently, the pioneer method, the complement-dependent cytotoxicity, has been integrated but has not been replaced by more-sensitive so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Human immunology

دوره 70 7  شماره 

صفحات  -

تاریخ انتشار 2009