Proton Radiation Damage Study of the Next Generation of Swept Charge Devices
نویسنده
چکیده
The first generation of Swept Charge Device (SCD) the e2v technologies plc CCD54 was used in the Demonstration of a Compact Imaging X-ray Spectrometer (D-CIXS) launched in 2003 and again in the Chandrayaan-1 X-ray Spectrometer (C1XS) instrument currently in orbit around the Moon. The main source of decreased energy resolution in both cases is proton damage, from trapped and solar protons respectively. This paper presents the results from an experimental study to evaluate the performance of the next generation of SCD the CCD234 and CCD236 irradiated with a 10 MeV equivalent proton fluence of 3.0×10 8 protons.cm -2 , demonstrating the factor of two increase in radiation hardness when compared to the CCD54. In particular the increased dark current, decrease in energy resolution and the degradation of charge transfer efficiency (CTE) are described.
منابع مشابه
Performance of new generation swept charge devices for lunar x-ray spectroscopy on Chandrayaan-2
The Chandrayaan-2 Large Area Soft X-ray spectrometer (CLASS) is due to be launched by the Indian Space Research Organisation (ISRO) in 2014. It will map the elemental composition of the lunar surface, building on the Chandrayaan-1 X-ray spectrometer (C1XS) heritage. CLASS will use an array of e2v technologies CCD236 swept charge devices (SCD) providing an active detector area of approximately 6...
متن کاملSecondary Particles Produced by Hadron Therapy
Introduction Use of hadron therapy as an advanced radiotherapy technique is increasing. In this method, secondary particles are produced through primary beam interactions with the beam-transport system and the patient’s body. In this study, Monte Carlo simulations were employed to determine the dose of produced secondary particles, particularly neutrons during treatment. Materials and Methods I...
متن کاملThe effect of protons on E2V Technologies L3Vision CCDs
The effect of different 10 MeV equivalent proton fluences on the performance of E2V Technologies (formerly Marconi applied technologies, formerly EEV) L3Vision Charge Coupled Devices (CCDs) was investigated. The first experimental radiation damage results of the L3Vision device are presented, with emphasis given to the analysis of damage to the gain register of the device. Changes in dark curre...
متن کاملA Comparative Study of Proton Radiation Damage in p- and n- Channel CCDs
It has been demonstrated that p-channel charge coupled devices (CCDs) are more radiation hard than conventional nchannel devices as they are not affected by the dominant electron trapping caused by the displacement damage defect the E-centre (phosphorus-vacancy). This paper presents a summary of the results from a comparative study of n-channel and p-channel CCDs each type operated under the sa...
متن کاملA comparison of arrived dose to the heart in the treatment of breast cancer in different modes of proton radiation by proton therapy using Monte Carlo simulation
Introdution: Today, the Advantages of radiation therapy by charged particles is indicated for the treatment of cancerous. During the passing of proton beam in the body tissues, secondary particles produce, which penetrate to the body healthy tissues and cause damage. The aim of this research was calculating the Spread out Bragg Peak for covering the breast cancer and investigating arrived dose ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010