Prospective validation of single plasma sample 99mTc-ethylenedicysteine clearance in adults.

نویسندگان

  • L Kabasakal
  • M Halaç
  • A F Yapar
  • E Alkan
  • B Kanmaz
  • C Onsel
  • K Sönmezoğlu
  • M Ayaz
  • B Kalender
  • H B Sayman
  • I Uslu
چکیده

UNLABELLED 99mTc-L,L-ethylene, L, dicysteine (EC) clearance shows strong correlation with orthoiodohippurate clearance, and it is possible to estimate effective renal plasma flow from 99mTc-EC clearance. In routine clinical studies, it is practical to use the one or two plasma sample method instead of multiple plasma samples for clearance determination. A single-sample technique was developed for 99mTc-EC, and a regression formula was generated. A prospective study tested the validity of this regression formula. METHODS The study population was composed of 26 patients with a wide range of renal function. Multiple plasma sample 99mTc-EC clearances were calculated from all patients using the open two-compartment model. Single plasma sample clearances were also determined from the 54-min plasma sample using the regression formula published previously. RESULTS The multiple-sample plasma clearance of 99mTc-EC ranged from 46 to 668 mL/min with a mean of 300.76 +/- 150.73 mL/min. The clearances obtained from the 54-min plasma sample ranged from 49 to 699 mL/min, with a mean of 297.39 +/- 152.23 mL/min. There was an excellent correlation between the clearances obtained by the two techniques (r = 0.99, slope = 0.9911). The standard error of estimation was found to be 25.9 mL/min. CONCLUSION This study suggests that 99mTc-EC clearance can be estimated from 54-min plasma samples with an acceptable error of estimation for most routine clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ethylenedicysteine versus diethylenetriamine pentaacetic acid as the carrier of technetium Tc 99m in diuretic renography for patients with upper urinary tract obstruction.

INTRODUCTION L,L-ethylenedicysteine (EC) is a new carrier of technetium Tc 99m (99mTc) with a lower affinity to plasma albumin in comparison with diethylenetriamine pentaacetic acid (DTPA). We compared 99mTc-EC scan with 99mTc-DTPA scan in diuretic renography for patients with obstructive uropathy. MATERIALS AND METHODS Thirty-three patients with upper urinary tract obstruction were randomly ...

متن کامل

Prediction of the structural and spectral properties for L,L-ethylenedicysteine diethylester (EC) and its complex with Technetium-99m radionuclide

The technetium-99m complex of the L,L-ethylenedicysteine diethylester (EC), of the brain imaging agent, was reported as a good choice for replacement of the renal nuclear medicines like OIH radiopharmaceutical. This present research work studies the structural, electronic and spectral properties of the EC compound and its complex with technetium-99m radionuclide from theoretical insight. All co...

متن کامل

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

Simultaneous measurement of renal clearance and plasma clearance of 99mTc-labelled diethylenetriaminepenta-acetate, 51Cr-labelled ethylenediaminetetra-acetate and inulin in man.

The present investigation was undertaken to study the kinetics of 99mTc-labelled diethylenetriaminepenta-acetate (DTPA) as compared with inulin and 51Cr-labelled ethylenediaminetetra-acetate (EDTA). Twenty patients with various degrees of decreased renal function were studied. The renal clearance, plasma clearance and volume of distribution of all three tracers were measured after a simultaneou...

متن کامل

A Bayesian 3-compartment model for 99mTc-MAG3 clearance.

UNLABELLED Because recent reports have questioned the traditional 2-compartment model for calculating tracer clearance after a single intravenous injection, a 3-compartment model was evaluated in this study. METHODS Bayesian statistics were used, which facilitated curve fitting by treating all subjects simultaneously. (99m)Tc-Mercaptoacetyltriglycine clearance data from 154 adults and 109 chi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 1999