Automatic Local Effect of Window/Level on 3-D Scale-Space Ellipsoidal Filtering on Run-Off-Arteries from White Blood Contrast-Enhanced Magnetic Resonance Angiography

نویسندگان

  • Jasjit S. Suri
  • Kecheng Liu
چکیده

Pre-filtering is a critical step in 3-D segmentation of the blood vessel and its display. This paper presents the local effect of window/level over the 3-D scale-space approach for filtering the white blood angiographic volumes and its implementation issues. The raw MR angiographic volume is first converted to an isotropic volume, and then the window/level is automatically adjusted slice by slice and a composite volume is generated. Then, 3-D edges are generated using the separable Gaussian derivative convolution with known scales. The edge volume is then run by the directional processor at each voxel where the eigenvalues of the 3-D ellipsoid are computed. The vessel score per voxel is then estimated based on these three eigenvalues which suppress the non-vasculature and background structures, yielding the filtered volume. The filtered volume is ray-cast to generate the maximum intensity projection images for display. The performance of the system is evaluated by computing the mean, variance, SNR and CNR images. We compare the filtering results with and without the usage of the local effect of window/level over 3-D scalespace ellipsoidal filtering. We show that the automatic window/level is effective in detecting small vessels which are otherwise difficult to extrapolate them. The system was run over 20 patient studies from different parts of the body such as: brain, abdomen, kidney and knee/ankle. The computer program takes around 150 seconds of processing time per study for a study for a data size of , which includes the complete performance evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Local Effect of Window/Level on 3-D Scale-Space Ellipsoidal Filtering on Run-Off-Arteries from White Blood Magnetic Resonanc Angiography

Pre-filtering is a critical step in 3-D segmentation of the blood vessel and its display. This paper presents the local effect of window/level over the 3-D scale-space approach for filtering the white blood angiographic volumes and its implementation issues. The raw MR angiographic volume is first converted to an isotropic volume, and then the window/level is automatically adjusted slice by sli...

متن کامل

An Enhanced Median Filter for Removing Noise from MR Images

In this paper, a novel decision based median (DBM) filter for enhancing MR images has been proposed. The method is based on eliminating impulse noise from MR images. A median-based method to remove impulse noise from digital MR images has been developed. Each pixel is leveled from black to white like gray-level. The method is adjusted in order to decide whether the median operation can be appli...

متن کامل

Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phase images and mask images to generate an optimal summary arteriogram. A paired ...

متن کامل

Three-dimensional adaptive filtering in magnetic resonance angiography.

In order to enhance 3D image data from magnetic resonance angiography (MRA), a novel method based on the theory of multidimensional adaptive filtering has been developed. The purpose of the technique is to suppress image noise while enhancing important structures. The method is based on local structure estimation using six 3D orientation selective filters, followed by an adaptive filtering step...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001