Dual wavelength laser diode excitation source for 2D photoacoustic imaging

نویسندگان

  • Thomas J. Allen
  • Paul C. Beard
چکیده

Photoacoustic methods can be used to make spatially resolved spectroscopic measurements of blood oxygenation when using a multiwavelength excitation source, such as an OPO system. Since these excitation sources are usually expensive and bulky, an alternative is to use laser diodes. A fibre coupled laser diode excitation system has been developed, providing two wavelengths, 850 and 905nm, each composed of 6 high peak power pulsed laser diodes. The system provided variable pulse durations (65-500ns) and repetition rates of up to 5KHz. The pulse energies delivered by the excitation system at 905nm and 850nm were measured to be 120μJ and 80μJ respectively for a 200ns pulse duration. To demonstrate the utility of the system, the excitation source was combined with an ultrasound detector to form a probe for in vivo single point measurements of superficial blood vessels. Changes in blood oxygenation and volume in the finger tip were monitored while making venous and arterial occlusions. To demonstrate the imaging capability of the excitation system, 2D photoacoustic images of a physiologically realistic phantom were obtained for a range of pulse durations using a cylindrical scanning system. The phantom was composed of cylindrical absorbing elements(μa = 1mm ) of 2.7mm diameter, immersed in a 1% intralipid solution (μs = 1mm ). This study demonstrated the potential use of laser diodes as an excitation source for photoacoustic imaging of superficial vascular structures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The advantage of using a diode laser instead of a Q-switched laser in photoacoustic imaging of tissues

Photoacoustic (PA) imaging of biological tissues using laser diodes instead of conventional Q switched pulsed systems provides an attractive alternative for biomedical applications. However, the relatively low energy of laser diodes operating in the pulsed regime, results in generation of very weak acoustic waves, and low signal-to-noise ratio (SNR) of the detected signals. This problem can be ...

متن کامل

High frame rate photoacoustic imaging at 7000 frames per second using clinical ultrasound system.

Photoacoustic tomography, a hybrid imaging modality combining optical and ultrasound imaging, is gaining attention in the field of medical imaging. Typically, a Q-switched Nd:YAG laser is used to excite the tissue and generate photoacoustic signals. But, such photoacoustic imaging systems are difficult to translate into clinical applications owing to their high cost, bulky size often requiring ...

متن کامل

A Portable Laser Photoacoustic Methane Sensor Based on FPGA

A portable laser photoacoustic sensor for methane (CH₄) detection based on a field-programmable gate array (FPGA) is reported. A tunable distributed feedback (DFB) diode laser in the 1654 nm wavelength range is used as an excitation source. The photoacoustic signal processing was implemented by a FPGA device. A small resonant photoacoustic cell is designed. The minimum detection limit (1σ) of 1...

متن کامل

Generating photoacoustic signals using high-peak power pulsed laser diodes

Photoacoustic signals are usually generated using bulky and expensive Q-switched Nd:YAG lasers, with limited scope for varying the pulse repetition frequency, wavelength and pulse width. An alternative would be to use laser diodes as excitation sources; these devices are compact, relatively inexpensive, and available in a wide variety of NIR wavelengths. Their pulse duration and repetition rate...

متن کامل

Three dimensional photoacoustic imaging of vascular anatomy in small animals using an optical detection system

A 3D photoacoustic imaging instrument for characterising small animal models of human disease processes has been developed. The system comprises an OPO excitation source and a backward-mode planar ultrasound imaging head based upon a Fabry Perot polymer film sensing interferometer (FPI). The mirrors of the latter are transparent between 590 – 1200nm but highly reflective between 1500-1600nm. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007