Morphology of the human tricuspid valve.

نویسندگان

  • M D Silver
  • J H Lam
  • N Ranganathan
  • E D Wigle
چکیده

The morphology of 50 normal tricuspid valves was studied. The surface of the leaflets was divided into three zones: (1) the rough zone, into which most of the chordae tendineae are inserted, (2) the basal zone, and (3) the clear zone, which lies between the rough and basal zones. Five types of chordae were distinguished by their morphology and mode of insertion: fan-shaped, rough zone, basal, free edge, and deep chordae. The last two types

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Fabrication and characterization of nanofibrous tricuspid valve scaffold based on polyurethane for heart valve tissue engineering

Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...

متن کامل

Rupture of chorda tendineae of the tricuspid valve in a horse: a case report

A2-year-old cachectic cross-breed gelding was admitted toVeterinary Teaching Hospital of University of Tehran followingthe onset of a marked respiratory distress, coughing and ventraledema. Clinical examinations indicated harsh respiratory andexpiratory sounds as well as jugular vein distention. Therespiratory and heart rates were 35/min and 60 bpm, respectively.Agrade III/IV pansystolic murmur...

متن کامل

eComment: re: three-dimensional transesophageal echocardiography in Ebstein's anomaly.

Three-dimensional (3D) transthoracic echocardiography has advantages over traditional two-dimensional (2D) echocardiography in visualizing tricuspid valve morphology in Ebstein's anomaly. We describe the application of intra-operative 3D transesophageal echocardiography during a tricuspid valve repair procedure in a patient with Ebstein's anomaly. Intra-operatively three-dimensional transesopha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 1971