A microcontroller based pacemaker tester

نویسنده

  • D. Radhakrishnan
چکیده

The design of a microcontroller based pacemaker tester is presented in this paper. Both invasive and noninvasive (transthoracic) pacemakers can be tested using this device. Two test loads are provided; a 500 ohms load for testing invasive pacemakers and a 50 ohms load for testing non-invasive pacemakers. A two line LCD display is used to indicate the test parameters, test results and the test in progress. The test results can be conveniently transferred to a PC or to a printer through the RS232C serial port provided. The unit can be packaged inside a small package and hence can be used as a handheld tester.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Consolidated Review on Embedded Micro-Controllers for Pace Maker Applications

This review paper is based on the real world applications of various microcontrollers in the field of pacemakers. The study conducted is based on various factors such as cost, power consumption, power saving, reliability, efficiency etc. These features differentiate each microcontroller from the other. The goal of this study is to study each microcontroller that are being employed in the field ...

متن کامل

APPLIED HW/SW CO-DESIGN: Using the Kendall Tau Algorithm for Adaptive Pacing

Microcontrollers, the brains of embedded systems, have found their way into every aspect of our lives including medical devices such as pacemakers. Pacemakers provide life supporting functions to people therefore it is critical for these devices to meet their timing constraints. This thesis examines the use of hardware co-processing to accelerate the calculation time associated with the critica...

متن کامل

Design and Implementation of the Predictive Current Control Strategy in the Single Phase Photovoltaic Grid-Connected Inverter Based on Microcontroller

In this paper, photovoltaic (PV) grid-connected inverter which is the core device in PV grid-connected system has been in depth research.An improved predictive current controller has been developed by the Authors for single-phase grid-connected voltage source inverters (VSI).Based on DSP TMS320LF2407A, a 10 kW single-phase grid-connected inverter has been built in this paper.Thus is aimed at us...

متن کامل

Ecg Simulator for Testing and Servicing Cardiac Monitors and Electrocardiographs

This paperwork presents the design and test of a microcontroller-based ECG (electrocardiogram) simulator. The ECG simulator is capable of generating nine ECG signals and a calibrated square wave (1 Hz, 1 mV at Lead II). The synthesized signals are: normal sinus rhythm (60 beats per minute – BPM, and 90 BPM), sinus bradycardia (30 BPM), sinus tachycardia (120, 180 and 240 BPM), sinus rhythm with...

متن کامل

Digital Integrated Circuit Tester ( Using AT 89 s 51 Microcontroller )

The Digital Integrated Circuit Tester implemented as in this paper is capable of testing 14 pin Integrated Circuits (ICs) of 7400 series. First, the system welcomes the user and asks the user to enter IC number. It takes the last two digits of the IC no. of the IC to be tested as input from a 4x3 matrix keyboard which is implemented by 12 push buttons. It then checks the IC(in the 14 pin socket...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000