The Ability of 10-2 Short-Wavelength Perimetry in Detecting Functional Loss of the Macular Area in Preperimetric Glaucoma Patients.

نویسندگان

  • Younhea Jung
  • Hae-Young L Park
  • Hyun Jin Jeong
  • Seung Yong Choi
  • Chan Kee Park
چکیده

PURPOSE To better understand functional loss in the macular area of preperimetric glaucoma patients exhibiting structural loss by exploring correlations between parameters of the ganglion cell-inner plexiform layer (GCIPL) and 10-2 short-wavelength perimetry (SWAP). METHODS One hundred thirty-four patients underwent 10-2 SWAP and conventional 24-2 visual field (VF) testing using a Humphrey field analyzer and macular scanning via Cirrus optical coherence tomography (OCT). Correlations between GCIPL thickness (GCIPLT) and the mean sensitivity (MS) of topographically corresponding areas explored in various VF tests were calculated. Correlations between GCIPL parameters and MS of the VF, in terms of the asymmetries of various VF sectors, were also determined. RESULTS Glaucoma patients, preperimetric by standard 24-2 VF analysis but exhibiting GCIPL thinning, had lower MS in 10-2 SWAP and central 24-2 VF analyses. The correlations between average GCIPLT and the corresponding MS were significant for both 10-2 SWAP (r = 0.291, P = 0.018) and 24-2 standard automated perimetry (r = 0.235, P = 0.029). The associations between sectoral GCIPLT and the corresponding 10-2 SWAP MS were significant for all sectors, with the highest correlation evident in the inferotemporal (r = 0.324, P = 0.009) and the lowest in the superonasal GCIPL sectors (r = 0.214, P = 0.043). Asymmetric relationships between GCIPLT and 10-2 SWAP MS exhibited similar yet stronger correlations. CONCLUSIONS Preperimetric glaucoma patients exhibiting structural loss in the macula also had functional loss revealed by 10-2 SWAP, which was less prominent in conventional 24-2 VF. Therefore, if structural abnormality is evident in the macular area, the central VF areas should be further examined even if the standard 24-2 data appear to be normal.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depression and Quality of Life in Patients with Glaucoma

Purpose: To investigate the frequency of depression and quality of life in patients with glaucoma. Methods: This cross-sectional study included 204 patients (102 males and 102 females) with a mean age of 58.9±11.96 and a range of 40 to 85 years old. Achromatic perimetry was performed, using the HFA SITA-standard 24-2. Severity was stratified according to the Nelson Glaucoma Severity Scale (base...

متن کامل

[Importance of central corneal thickness when studying ocular hypertensive eyes, glaucoma suspects and preperimetric glaucomatous eyes].

PURPOSE To compare the central corneal thickness, measured with an ultrasound pachymeter, in normal subjects, those with ocular hypertension, glaucoma suspects and patients with preperimetric glaucoma. METHODS 61 normal eyes (control group), 131 eyes with ocular hypertension, 62 glaucoma suspects (optic nerve head morphology compatible with glaucoma) and 36 patients with preperimetric glaucom...

متن کامل

Long-term follow-up in preperimetric open-angle glaucoma: progression rates and associated factors.

PURPOSE To investigate the rate of progressive visual field (VF) loss and associated factors for structural or functional progression in preperimetric open-angle glaucoma (OAG). DESIGN Longitudinal, observational study. METHODS We included 127 eyes of 127 preperimetric OAG patients who were treated with topical medication and followed for more than 5 years. All patients underwent stereo opt...

متن کامل

A combined index of structure and function for staging glaucomatous damage.

OBJECTIVES To present and evaluate a new combined index of structure and function (CSFI) for staging and detecting glaucomatous damage. METHODS Observational study including 333 glaucomatous eyes (295 with perimetric glaucoma and 38 with preperimetric glaucoma) and 330 eyes of healthy subjects.All the eyes were tested with standard automated perimetry and spectral domain optical coherence tom...

متن کامل

Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 56 13  شماره 

صفحات  -

تاریخ انتشار 2015