Immunoturbidimetric assay for rheumatoid factor using an enzyme

نویسندگان

  • AC LAFONG
  • E CROTHERS
چکیده

receiving full dose heparin (A kaolin clotting time; 56, 29, and 19 seconds) and four had been considered to have equivocal lupus inhibitor tests. On testing of subsequent samples from three of the equivocal patients, one with a A kaolin clotting time of 29 seconds was found to have a definite lupus inhibitor while the two others (19 and 14 seconds) were negative. The A kaolin clotting time in the two positive patients with normal PTTKs was 14 and 34 seconds and in the positive patients with normal APTTs the A kaolin clotting time range was 14-150 seconds with a mean (SD) of 24-6 (21-6) seconds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved immunoturbidimetric method for rheumatoid factor testing.

The performance of two immunoturbidimetric modifications for rheumatoid factor (RF) testing, which differ with respect to the means of complement inactivation (heat treatment and inactivation with polyvinyl sulphonate), were compared in serum samples from 87 patients with rheumatoid arthritis (RA) and from 403 healthy subjects. IgM-rheumatoid factor titres were also measured with an enzyme link...

متن کامل

Immunoturbidimetric assay for rheumatoid factor using an enzyme immunoassay microplate reader.

receiving full dose heparin (A kaolin clotting time; 56, 29, and 19 seconds) and four had been considered to have equivocal lupus inhibitor tests. On testing of subsequent samples from three of the equivocal patients, one with a A kaolin clotting time of 29 seconds was found to have a definite lupus inhibitor while the two others (19 and 14 seconds) were negative. The A kaolin clotting time in ...

متن کامل

Evaluation of a quantitative immunoturbidimetric assay for rheumatoid factors.

A quantitative immunoturbidimetric assay for rheumatoid factors (RF) is described, based on the immunoprecipitation between aggregated human IgG and rheumatoid factors in serum. The resulting turbidity is measured photometrically at 340 nm. The method is standardized against the WHO international reference preparation and the results are expressed in international units per milliliter (int. uni...

متن کامل

Potency of Enzymes from Renal Tubules as Biotracers in Rheumatoid Arthritis Patients Treat With Most Used Antirheumatic Drugs

Aim: To estimate the effect of initial therapy with Paracetamol and Ketoprofen on glomerular and tubular integrity in patients with Rheumatoid arthritis (RA), to quantify the toxicity of these drugs through measurements of the enzyme excretion that correlates with the damage degree on the tubular epithelium. Microalbuminuria is used as a marker for glomerular damage, and the urinary excretion o...

متن کامل

Latex immunoturbidimetric assay for soluble fibrin complex.

BACKGROUND Soluble fibrin complex (SFC), composed of fibrin monomer and fibrinogen derivatives, is known to exist in the circulating blood in patients with thrombosis. Its detection and quantification are useful for obtaining information about the condition and degree of intravascular coagulation in early-stage thrombosis, but there is no rapid method to measure SFC in plasma for clinical use. ...