The Vicenza wearable artificial kidney for peritoneal dialysis (ViWAK PD).
نویسندگان
چکیده
BACKGROUND The study describes the structure and operational characteristics of a new wearable system for continuous ambulatory peritoneal dialysis (CAPD) for chronic kidney disease patients. METHODS We designed a wearable system consisting of: (1) a double lumen peritoneal catheter; (2) a dialysate outflow line; (3) a miniaturized rotary pump; (4) a circuit for dialysate regeneration featuring a waterproof container with 4 cartridges in parallel with a mixture of activated carbon and polystyrenic resins; (5) a filter for deaeration and microbiological safety; (6) a dialysate inflow line, and (7) a handheld computer as a remote control. The system has been tested circulating 12 liters of exhausted PD solution through the experimental adsorption unit at a rate of 20 ml/min. Creatinine, beta2-microglobulin (beta2-MG) and angiogenin were measured before and after the adsorption unit at baseline, and after 4 and 10 h of use. RESULTS The cartridges containing polystyrenic resin completely removed beta2-MG and angiogenin from the fluid batch. Those with the activated carbon removed completely urea and creatinine. The final result was 11.2 liters of net solute clearance. The system is designed to be used as follows: The peritoneal cavity is loaded in the morning with 2 liters of fresh PD solution. After 2 h, when dialysate/plasma equilibration at approximately 50% has occurred, recirculation is activated for 10 h at a rate of 20 ml/min. After this period, recirculation stops and glucose is optionally added to the peritoneal cavity to achieve ultrafiltration if needed. After 2 h the fluid is drained and a 2-liter icodextrin exchange is performed overnight to achieve further ultrafiltration. The clearance provided by the minicycler is further increased by the 2-liter exchange and the overnight exchange. Therefore, the system operates 24 h/day and provides creatinine and beta2-MG clearance in the range of 15-16 liters/day, corresponding to a weekly clearance of 100-110 liters. The patient reduces the number of exchanges compared to CAPD and uses less fluid than in automated peritoneal dialysis (APD). Furthermore, the handheld computer allows for prescription and assessment of the therapy providing information on cartridge saturation, flow and pressure conditions and offering the possibility of remote wireless control of operations. Some problems still remain to be solved in the present configuration including the addition of an injection system for glucose and bicarbonate when needed, a system to reduce fibrin delivery to the sorbent and finally a more complex mixture of sorbents to make sure a complete removal of small molecules including urea is achieved. CONCLUSION The wearable PD system may become a possible alternative to APD or CAPD reducing the time dedicated to perform exchanges and improving peritoneal dialysis adequacy and patient's rehabilitation.
منابع مشابه
The future of the artificial kidney: moving towards wearable and miniaturized devices.
New directions in dialysis research include cheaper treatments, home based therapies and simpler methods of blood purification. These objectives may be probably obtained with innovations in the field of artificial kidney through the utilization of new disciplines such as miniaturization, microfluidics, nanotechnology. This research may lead to a new era of dialysis in which the new challenges a...
متن کاملPortable or wearable peritoneal devices--the next step forward for peritoneal dialysis?
Peritoneal dialysis can be considered a "wearable" dialysis therapy. However, patients typically require 3 or 4 daily exchanges, each taking 20-40 minutes and potentially increasing the risk of infection by repeated disconnection and reconnection. Although peritoneal dialysis cyclers allow patients to be "free" from their machine for 13-15 hours, they similarly need a supply of fresh dialysate....
متن کاملCorrelational studies on insulin resistance and leptin gene polymorphisms in peritoneal dialysis patients
Objective(s):The aim of the study was to investigate the relationship between insulin resistance (IR) and leptin (LEP) gene polymorphisms in peritoneal dialysis (PD) patients. Materials and Methods: From July 1, 2011 to August 1, 2011, patients who received chronic PD were chosen and divided into three groups (DM, high HOMR-IR, and low HOMR-IR). Two PCR products of LEP were sequenced and aligne...
متن کاملComparison of Marital Satisfaction in Hemodialysis and Peritoneal Dialysis Patients
Alternative kidney treatments, including renal transplantation, hemodialysis (HD), and peritoneal dialysis (PD), are administered when severe kidney failure occurs and the kidney can no longer function. The present study compares different dimensions of marital satisfaction in HD and PD patients so as to assist physicians and patients in choosing their appropriate treatment. This cross-se...
متن کاملComparison of the Effects of Using Self-regulation Theory and self-care Education on Medical Adherence in Patients Receiving Peritoneal Kidney Dialysis
Background: Medical adherence is critical to peritoneal dialysis (PD) success. Accordingly, the self-regulation approach plays a crucial role in disease management and treatment progress through the formation of an organized pattern of beliefs in patients. Aim: The purpose of this study was to compare the effects of self-regulation theory (SRT) and self-care training on medical adherence in pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Blood purification
دوره 25 4 شماره
صفحات -
تاریخ انتشار 2007