MG-63 osteoblast-like cell proliferation on auxetic PLGA scaffold with mechanical stimulation for bone tissue regeneration
نویسندگان
چکیده
BACKGROUND Auxetic scaffolds (experimental) was fabricated by using poly(D, L-lactic-co-glycolic acid), 50:50, (PLGA) for effective bone cell proliferation with mechanical stimulation. METHODS Negative Poisson's ratio in scaffold, 3-directional volumetric compression was applied during the scaffold fabrication at adequate temperature (60 °C). The pore size of scaffold ranged between 355 and 400 μm. RESULTS The porous morphology of the prepared auxetic scaffolds had shown partially concave and dent shapes in SEM image as expected. The lowest Poisson's ratios of experimental group was -0.07 at 60 °C/10 min. Compressive strength of experimental group was shown about 3.12 times higher than control group (conventional scaffold) in dry state at 25 °C. The compressive strengths of both groups were tended to be decreased dramatically in wet state compared to in dry state. However, compressive strengths of experimental group were higher 3.08 times and 1.88 times in EtOH/PBS (25 °C) and EtOH/PBS/DMEM (37 °C) than control group in wet state, respectively. Degradation rate of the scaffolds showed about 16 % weight loss in 5 weeks. In cell attachment test, experimental group showed 1.46 times higher cell proliferation than control group at 1-day with compressive stimulation. In 3-day culture, the experimental group showed 1.32 times higher than control group. However, there was no significant difference in cell proliferation in 5-day cultivation. CONCLUSION Overall, negative Poisson's ratio scaffolds with static mechanical stimulation could affect the cell proliferation at initial cultivation time.
منابع مشابه
MG-63 cells proliferation following various types of mechanical stimulation on cells by auxetic hybrid scaffolds
BACKGROUND Mechanical properties and cyto-compatibility of a composite scaffold which possessed negative (-) Poisson's ratio (NPR) was investigated for effective load transfer from auxetic scaffold to cell. METHODS Organic/inorganic composite scaffolds were prepared by mixing hydroxyapatite (HA) to poly(lactide-co-glycolide) (PLGA). To induce NPR in composite scaffold, 3-directional volumetri...
متن کاملElectrospun biocompatible Gelatin-Chitosan/Polycaprolactone/Hydroxyapatite nanocomposite scaffold for bone tissue engineering
In recent years, nanocomposite scaffolds made of bioactive polymers have found multiple applications in bone tissue engineering. In this study composite nanofibrous structure of gelatin (Gel)/chitosan (Cs)-polycaprolactone (PCL) containing hydroxyapatite (HA) were fabricated using co-electrospinning process. To assay the biocompatibility and bioactivity of electrospun nanocomposite scaffolds, t...
متن کاملElectrospun biocompatible Gelatin-Chitosan/Polycaprolactone/Hydroxyapatite nanocomposite scaffold for bone tissue engineering
In recent years, nanocomposite scaffolds made of bioactive polymers have found multiple applications in bone tissue engineering. In this study composite nanofibrous structure of gelatin (Gel)/chitosan (Cs)-polycaprolactone (PCL) containing hydroxyapatite (HA) were fabricated using co-electrospinning process. To assay the biocompatibility and bioactivity of electrospun nanocomposite scaffolds, t...
متن کاملComparison of Proliferation and Osteoblast Differentiation of Marrow-Derived Mesenchymal Stem Cells on Nano- and Micro-Hydroxyapatite Contained Composite Scaffolds
Bones constructed by tissue engineering are being considered as valuable materials to be used for regeneration of large defects in natural bone. In an attempt to prepare a new bone construct, in this study, proliferation and bone differentiation of marrow-derived mesenchymal stem cells (MSCs) on our recently developed composite scaffolds of nano-, micro-hydroxyapatite/ poly(l-lactic acid) were ...
متن کاملIn vitro and in vivo evaluation of electrospun PCL/PMMA fibrous scaffolds for bone regeneration
Scaffolds were fabricated by electrospinning using polycaprolactone (PCL) blended with poly(methyl methacrylate) (PMMA) in ratios of 10/0, 7/3, 5/5 and 3/7. The PCL/PMMA ratio affected the fiber diameter, contact angle, tensile strength and biological in vitro and in vivo properties of the scaffolds, and the 7/3 ratio resulted in a higher mechanical strength than 5/5 and 3/7. In vitro cytotoxic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 20 شماره
صفحات -
تاریخ انتشار 2016