Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time.
نویسندگان
چکیده
BACKGROUND Targets for radiofrequency (RF) ablation of atrial fibrillation, atrial flutter, and nonidiopathic ventricular tachycardia are increasingly being selected on the basis of anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures and is associated with radiation risk, other approaches to mapping may be beneficial. METHODS AND RESULTS An electromagnetic catheter positioning system was superimposed on 3D MR images using fiducial markers. This allowed the dynamic display of the catheter position on the true anatomy of previously acquired MR images in real time. In vitro accuracy and precision during catheter navigation were assessed in a phantom model and were 1.11+/-0.06 and 0.30+/-0.07 mm (mean+/-SEM), respectively. Left and right heart catheterization was performed in 7 swine without the use of fluoroscopy, yielding an in vivo accuracy and precision of 2.74+/-0.52 and 1.97+/-0.44 mm, respectively. To assess the reproducibility of RF ablation, RF lesions were created repeatedly at the identical anatomic site in the right atrium (n=8 swine). Average distance of the repeated right atrial ablations was 3.92+/-0.5 mm. Straight 3-point lines were created in the right and left ventricles to determine the ability to facilitate complex ablation procedures (n=6 swine). The ventricular lesions deviated 1.70+/-0.24 mm from a straight line, and the point distance differed by 2.25+/-0.63 mm from the pathological specimen. CONCLUSIONS Real-time display of the catheter position on 3D MRI allows accurate and precise RF ablation guided by the true anatomy. This may facilitate anatomically based ablation procedures in, for instance, atrial fibrillation or nonidiopathic ventricular tachycardia and decrease radiation times.
منابع مشابه
Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملPotency of integrating three-dimensional cardiac magnetic resonance imaging into electroanatomic mapping to perform catheter ablation in pediatrics
Background Radio-frequency catheter ablation (RFCA) in children is difficult because the size of heart chamber change with age and the catheter made for adults is not appropriate for a child. Three-dimensional (3D) images for electroanatomic mapping (EAM) have been used to create from images of multi-detector computed tomography (MDCT) which need to perform entailed by contrast medium injection...
متن کاملFeasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo
BACKGROUND Clinical treatment of cardiac arrhythmia by radiofrequency ablation (RFA) currently lacks quantitative and precise visualization of lesion formation in the myocardium during the procedure. This study aims at evaluating thermal dose (TD) imaging obtained from real-time magnetic resonance (MR) thermometry on the heart as a relevant indicator of the thermal lesion extent. METHODS MR t...
متن کاملFrameless stereotaxy for surgery of the epilepsies: preliminary experience. Technical note.
Frameless stereotactic techniques used in conjunction with three-dimensional images allow accurate planning and performance of a variety of neurosurgical procedures. The authors have used the frameless stereotactic Allegro Viewing Wand system to provide real-time correlation of the operating field and computerized images in 42 neurosurgical operations, including 31 epilepsy procedures. The syst...
متن کاملIntracardiac Echocardiography during Catheter-Based Ablation of Atrial Fibrillation
Accurate delineation of the variable left atrial anatomy is of utmost importance during anatomically based ablation procedures for atrial fibrillation targeting the pulmonary veins and possibly other structures of the atria. Intracardiac echocardiography allows real-time visualisation of the left atrium and adjacent structures and thus facilitates precise guidance of catheter-based ablation of ...