Vibrational analysis of bioprosthetic heart valve leaflets using numerical models: effects of leaflet stiffening, calcification, and perforation.

نویسندگان

  • M S Hamid
  • H N Sabbah
  • P D Stein
چکیده

The fundamental natural frequency of the closed cusps of porcine bioprosthetic valves, fabricated from the normal leaflets of pig aortic valves, was estimated using a finite element model. Both normal and stiffened leaflets were considered in the vibrational analysis. The effects of conditions that simulated degeneration, such as stiffening, central perforation, a tear, calcium deposits in the commissural attachments, and combinations of these were determined. The primary frequency of vibration of the normal leaflets was within the range of the dominant frequency of the heart sounds determined clinically by spectral analysis of the recorded phonocardiogram. If only one leaflet was stiffened or calcified, there was only a marginal change of frequency. With stiffening and calcification of the commissures of all 3 leaflets, the frequency of vibration increased. Introduction of a tear in a single leaflet of a stiffened and calcified valve markedly reduced the fundamental frequency. In view of the relation between the frequency content of heart sounds and the frequency of valve vibration, this mathematical simulation establishes a possible basis for the observation of a varying dominant frequency of heart sounds in patients with bioprosthetic valves that are in the process of degenerating.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calcification of Porcine Aortic Valvular Interstitial Cells

Calcific aortic stenosis (AS), stiffening of aortic valve leaflets and narrowing of the aortic orifice, is the most common heart valve disease in developed countries [1]. The aortic valve is located between the aorta and the left ventricle and consists of 3 leaflets. Each leaflet contains outer endothelial layers and interstitial cells interspersed in the matrix between the endothelial layers. ...

متن کامل

Application of finite element analysis to the design of tissue leaflets for a percutaneous aortic valve.

Percutaneous Aortic Valve (PAV) replacement is an attractive alternative to open heart surgery, especially for patients considered to be poor surgical candidates. Despite this, PAV replacement still has its limitations and associated risks. Bioprosthetic heart valves still have poor long-term durability due to calcification and mechanical failure. In addition, the implantation procedure often p...

متن کامل

Analysis of hemodynamic indicators in Bicuspid Aortic Valves using a computational mathematical model

Bicuspid Aortic Valve (BAV) is a congenital cardiac disorder, prevalent in 1%–2% of the general population, where 33% of BAV patients may experience vascular complications. BAV consists in two cusps instead of three, as in a normal valve (Tricuspid Aortic Valve, TAV). This work is devoted to the numerical study of hemodynamic effects in different BAV geometries (2D) using a Fluid Structure I...

متن کامل

Kangaroo versus freestyle stentless bioprostheses in a juvenile sheep model: hemodynamic performance and calcification behavior.

BACKGROUND Glutaraldehyde-preserved bioprosthetic heart valve substitutes have limited performance and longevity due to tissue degeneration and calcification. The Freestyle valve (Medtronic Heart Valves, Inc, Minneapolis, MN) combines zero fixation pressure and proportional, variant-amino oleic acid (AOA) as antidegeneration and antimineralization measures. The aim of this study was to compare ...

متن کامل

Image-based immersed boundary model of the aortic root

Each year, approximately 300,000 heart valve repair or replacement procedures are performed worldwide, including approximately 70,000 aortic valve replacement surgeries in the United States alone. Computational platforms for simulating cardiovascular devices such as prosthetic heart valves promise to improve device design and assist in treatment planning, including patient-specific device selec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 61 5  شماره 

صفحات  -

تاریخ انتشار 1987