A Study on the Passive Microvalve Applicable to Drainage Device for Glaucoma

نویسنده

  • Tae Seok Sim
چکیده

−This paper reports the design, modeling, fabrication and measurement of passive microvalves, which are applicable to glaucoma implants. The proposed microvalves were designed using fluidic theory. The microvalves consisted of microchannels and chambers. The microchannels had a constant fluidic resistance generating a pressure difference. Six kinds of microvalves were designed using fluidic equations for laminar flow and fabricated to examine the influences of chamber size, channel length and the shape of channel cross section. The pressure difference between the designed microvalve and the fabricated microvalve was measured to be less than 4%. Index Terms− MEMS, Micro fluidics, Glaucoma, Passive, Microvavle

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stem ‍Cells in Glaucoma Management

Glaucoma is the leading cause of preventable blindness worldwide. Despite tremendous advances in medical and surgical management of glaucoma in the recent years, the prevalence of glaucoma related blindness is anticipated to increase in the future decades because of the aging population. Stem cells have the potential to change the glaucoma management in several ways. There are several areas of ...

متن کامل

مقایسه کاربرد وسیله جدید )کیسه تخلیه( با چست باتل برای تخلیه فضای پلور

    Background and Aim: Chest tube has been used as a close drainage system for evacuation of pleural cavity after thoracic surgery and in traumatic patients.Today, the chest bottles are made from hard and fragile  material that may be broken easily. Also chest bottle needs sterile saline solution for proper functioning. This causes heaviness with pressure effect on the chest wall, resulting in...

متن کامل

Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...

متن کامل

On-demand Control of Microfluidic Flow via Solenoid Microvalve Suction

A simple, low-cost and on-demand microfluidic controlling platform was developed based on a capillary-tuned solenoid microvalve suction effect without any outer pressure source. The suction effect was employed as a stable driving force for manipulating micro-fluid by connecting a piece of capillary tubing between the microvalve and the chip. The suction volume could be controlled from microlite...

متن کامل

A New Conveyable Device for Electro-drainage of Thorax

Chest tube is a flexible plastic tube used to discharge secretion in the cavity between the lungs and chest named pleural cavity. Normally, there is a small amount of fluid in the cavity between the lungs and chest; This fluid helps the movement of lungs during breathing without abrasion. Entrance of bit of air, blood or pus because injury in the pleural cavity can prevent the lungs from fully ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003