Transcatheter occlusion of a large coronary artery fistula using a patent ductus arteriosus occluder.
نویسندگان
چکیده
A large fistula from the left coronary artery to the right ventricle was successfully closed percutaneously in a 40 year-old patient using a patent ductus arteriosus occluder. The device was positioned and deployed via the venous system using a guidewire that had been advanced via the aorta, coronary artery and fistula to the venous circulation (arterio-venous loop creation). No complications were reported at follow-up.
منابع مشابه
Large coronary artery fistula and patent ductus arteriosus: transcatheter closure with three PDA nitinol wire mesh occluders
Coronary artery fistulas (CAF) are the most common congenital anomaly of this vessel. We present the case of a 26-year-old man with two coexisting congenital cardiac defects: patent ductus arteriosus (PDA) and CAF. The patient 3 months earlier had the transcatheter PDA closed (type A, diameter 4 mm) with a 10/8 mm PDA nitinol wire mesh occluder. After the procedure he continued to have symptoms...
متن کاملTranscatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.
Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...
متن کامل[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].
INTRODUCTION AND OBJECTIVES Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4....
متن کاملTranscatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder: Initial Results and Mid-Term Follow-Up
Received 11 March 2002. Accepted for publication 28 May 2002. Introduction and objectives. Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and midterm results of the treatment of PDA with the Amplatzer duct occluder. Patients and methods. From October 1999 to December 2001, 30 children underwent transcatheter clo...
متن کاملTranscatheter closure of large sized patent ductus arteriosus using the amplatzer duct occluder device.
OBJECTIVE To assess the results of anterograde transcatheter closure of a large sized patent ductus arteriosus using the Amplatzer Duct Occluder (ADO) device. STUDY DESIGN A case series. PLACE AND DURATION OF STUDY Department of Cardiology, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from January 2005 to December 2007. METHODOLOGY All patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Kardiologia polska
دوره 69 12 شماره
صفحات -
تاریخ انتشار 2011